Process plants, watched for leaks, fires and emissions.

Chemical and process plants handle substances that can leak, ignite or reach the neighbours. Fixed gas detection, thermal cameras, stack emission monitors and site weather, joined in one record, let operators find leaks sooner, prove permit compliance and tell emergency services where a release is heading.

Plan a deploymentHow it worksStation Builder
Industry
Industry
Measurements
5
Sources cited
5
  1. Industry · Chemical and process plants

    Hazards inside the fence, neighbours outside

    Chemical and process plants handle substances that can leak, ignite or drift toward homes and schools. The law asks them to prevent major accidents, limit consequences and keep emissions within their permits. Gas, fire, emissions and weather watched together make every one of those duties easier to meet.

  2. What is measured

    Gas, heat, stacks and wind

    Fixed detectors measure flammable and toxic gases at units, tank farms and fence lines. Thermal cameras watch units and storage for hot spots, automated systems measure stack emissions, and a weather station measures the wind and stability that decide where a release goes.

    Instruments
    Gas detectors · Thermal cameras · Stack emission monitors · Weather station
  3. The base node

    Where is it heading?

    The node joins gas readings with wind to estimate where a release is heading, confirms alarms with thermal images, computes emission averages against permit limits as they accumulate and keeps a signed record that the regulator can inspect. Every value is signed at the node before it leaves.

  4. Radio and links

    Fibre, behind a gateway

    Plants have fibre, and monitoring rides it to the control room and the environment team through a security gateway that keeps it apart from the control system. A private cellular network reaches temporary detectors during shutdowns. When one path fails, the other carries the data.

    Links
    Fibre · Private LTE
  5. How it works

    From a leak to a safe muster

    A flange leaks in a tank farm at night. Two detectors alarm, the thermal camera shows no fire, and the node estimates the plume heading toward the east fence on a light wind. Operators isolate the line, the east muster point is avoided, and emergency services are told the direction.

  6. From order to operation · Order

    Scope with the safety report

    The scope reads the site’s safety report, emissions permit, existing detection and stack monitors, emergency plans and the control system architecture. Nexus Observatory Inc. returns the monitoring design, joins to existing systems, security design and a price per site and per year.

    Plan a deployment
  7. From order to operation · Survey

    Survey units and fence lines

    Crews survey units, tank farms, stacks and fence lines with the site’s safety and environment engineers: detector positions for each hazard, camera views, weather station siting and network paths. Hazardous area classifications set what equipment may go where. Findings shape the kit for each site before anything is built.

  8. From order to operation · Permits

    Permits to work

    All work follows the site’s permits to work and hot work rules, equipment in hazardous areas is certified for its zone, and connecting monitoring to the network goes through the site’s change control. Every permit is kept with the site record.

  9. From order to operation · Build

    Build and certify

    Detectors, cameras and gateways are configured, certified equipment is checked against its zone, nodes are hardened and enrolled with their identities, and the whole system is tested with simulated alarms before it ships. Nothing ships until the whole kit has passed its tests together.

    Open the Station Builder
  10. From order to operation · Install

    Install during planned work

    Crews install detectors, cameras and the weather station during planned work, connect gateways and the node behind the security gateway, and photograph every point. Existing detectors and stack monitors are joined through their interfaces. Crews follow the site safety plan throughout the work.

  11. From order to operation · Commission

    Commission with gas tests

    Each node proves its identity. Every detector is bump-tested with calibration gas, cameras are checked with a heat source, stack monitor data are compared with the latest quality assurance results, and alarm routes are tested. Acceptance is recorded with the owner before handover.

  12. From order to operation · Operate

    One record for safety and permits

    Operators see gas, fire, emissions and weather together. Leaks are found and fixed sooner, emission averages are tracked against limits in real time, and in an incident emergency services receive where the release is heading. Every alert and action is kept on the record.

  13. From order to operation · Maintain

    Test, calibrate, report

    Detectors are calibrated and bump-tested on schedule, stack monitors follow their quality assurance cycle, cameras are cleaned and software patched in rings. Annual emissions reports and incident records come from the same signed record. Maintenance history stays with each site for its whole life.

    Book field services
  14. Data products

    For control rooms, environment and regulators

    Control rooms and emergency response teams receive gas and fire alarms with location; environment managers receive emission averages against permit limits; emergency services receive release direction in incidents; regulators receive emissions and incident reports, each signed and tied to unit and time.

    See the data products
  15. Evidence

    Safety report, permit and record

    Monitoring supports the major-accident hazards directive and industrial emissions permits, stack measurements follow the European quality assurance standard, gas detectors follow the international selection and maintenance standard, and the network follows the industrial security series. Every alarm and average is signed and kept.

    Drawn against
    Directive 2012/18/EU · Directive 2010/75/EU · EN 14181 · IEC 60079-29-2 · IEC 62443
  16. What you get

    Mine, plant and port site monitoring

    Slope radar, tailings monitoring, dust and water, and site connectivity for operations and closure. Delivered as managed service and hardware + software, for mining, heavy industry, ports. Scale: Site portfolios. Service levels are written as numbers you can measure on your own dashboard.

    Talk to sales
  17. Next step

    Plan chemical and process plants with us

    Tell us the site, the measurements and the rules it answers to. We reply with a survey proposal, a design and a scope for chemical and process plants. An engineer replies with a survey proposal and a scope, and the plan grows from one site to the network you need, at your pace.

    Plan a deploymentOpen the Station BuilderOpen the Studio

01The place and its hazards

Where it runs, and what can go wrong.

Operating contextEstablishments holding dangerous substances must prevent major accidents and limit their consequences under the major-accident hazards directive, large installations operate under industrial emissions permits with automated stack measurements quality-assured to the European standard, and flammable gas detectors are selected, installed and maintained to the international standard.

Hazards

  • Leaks of flammable and toxic gases
  • Fires spreading between units
  • Stack emissions above permit limits
  • Releases drifting toward homes and schools
  • Monitoring networks that are themselves a cyber entry point

02What must be measured

What, where, how often, and under which rules.

Each measurement names where it is taken, how often, and the public standard or regulation behind it. Numbers in the sources column open the cited source below.

MeasurementWhereCadenceSources
Flammable and toxic gas concentrationsFixed detectors at units, tank farms and fence linesContinuous, alarms in seconds12
Stack emissionsAutomated measuring systems on stacksContinuous, half-hourly and daily averages34
Hot spots and firesThermal cameras over units and storageContinuous2
Wind and stability for plume directionA weather station on the siteEvery minute2
Monitoring network securityThe site’s monitoring networkContinuous5

03The observation stack

From one base unit to a network.

The same blocks at every scale: instruments and a base node, a site with its radio, a fleet run as one, and a network federated on the open protocol.

  1. 01

    Base unit

    A unit point: gas detectors, a thermal camera and a weather sensor on an industrial gateway with an edge node.

    Build a station →
  2. 02

    Site

    A site: every unit, tank farm, stack and fence line on one node behind a security gateway, with fibre backhaul.

    Plan a site →
  3. 03

    Fleet

    Every site of an operator on one safety and environment view.

    Managed offers →
  4. 04

    Network

    Operators share emissions and incident records with regulators and emergency services through agreed formats.

    The open protocol →
  • 01Gas detector (industrial)
  • 02Thermal camera
  • 03Compact weather station
  • 04OT gateway (OPC UA, Modbus)
  • 05Edge node (Wedge)
  • 06Zero-trust gateway
  • 07Fibre terminal

Radio and links

Fibre

Plants have fibre; monitoring rides it to the control room and the environment team.

Radio and links

Private LTE

A private cellular network reaches temporary detectors during shutdowns and in units without cabling.

Edge computeThe node joins gas readings with wind to estimate where a release is heading, confirms alarms with thermal images, computes emission averages against permit limits and keeps a signed record for the regulator.

PowerMonitoring runs from the plant’s uninterruptible supply, so it keeps reporting during the power loss that may accompany an incident.

04How it works

From the instrument to the product.

One observation’s path, tier by tier, with the interface on every link and a bill of materials below; then how the one node grows to a site, a fleet and federated networks.

Chemical and process plants: data path

– of 08

01 Instruments Measurement with sensor identity andcalibration 02 Gateway 03 Node – Wrap in an observation envelope with timequality– Measure quality and uncertainty, attachquality flags– Buffer locally (store-and-forward when thelink drops) 04 Local network 05 Backhaul Commit with transactional outbox andpublish, delivered at least once 06 Site Consumer inbox deduplicates and applieseach record once into governed data 07 Data store Governed product through API, map orexport, correction-aware 08 Products OPC UAModbusMQTT 01 Gas detector (industrial) Analogue I/O · RS-485 · Ethernet 02 Thermal camera Ethernet 03 Compact weather station SDI-12 · RS-485 · Ethernet Automated stack emission measuringsystem Not in the reference kit 04 OT gateway (OPC UA, Modbus) Ethernet · RS-485 · CAN · AnalogueI/O 05 Edge node (Wedge) Ethernet · Fibre · USB · RS-485 ·BMC 06 Zero-trust gateway Ethernet · Fibre 07 Fibre terminal Fibre · Ethernet Site MQTT 5 with Sparkplug B Governed data store Versioned, correction-aware Gas and fire alarms with location Emission averages against permitlimits Release direction for incidents Emissions and incident reports RS-485 · Modbus RS-485 · Modbus Ethernet Ethernet · RTSP/ONVIF Ethernet · opc-ua Ethernet Fibre Fibre
From the instrument to the published product: each band is a tier, each connector names its interface, and the numbers match the bill of materials. Hover or focus a block to trace its path; scroll or step to follow one observation.
Bill of materials
ItemEquipmentData portsProtocolsPower in
01Gas detector (industrial)Fixed detector for flammable or toxic gas in industrial areas, with alarm outputs.Analogue I/ORS-485EthernetModbus, OPC UA, MQTT 524 V DC
02Thermal cameraLong-wave infrared camera for fire detection, equipment hot spots and night monitoring.EthernetRTSP with ONVIF profiles, MQTT 5PoE
03Compact weather stationAll-in-one or compact station for temperature, humidity, pressure, wind and rain at a site.SDI-12RS-485EthernetSDI-12, Modbus, MQTT 5, OGC SensorThings API12 V DC
04OT gateway (OPC UA, Modbus)Read-only bridge from industrial fieldbuses and controllers (Modbus, OPC UA, DNP3, IEC 61850, CAN) to the site network, behind a security boundary.EthernetRS-485CANAnalogue I/OOPC UA, Modbus, DNP3 (IEEE 1815), IEC 61850 (MMS, GOOSE), MQTT 524 V DC
05Edge node (Wedge)Rugged edge node that boots from signed media, attests itself and establishes a site cell from little or no infrastructure.EthernetFibreUSBRS-485BMCMQTT 5, DMTF Redfish, IEEE 1588 PTP, NTP with NTS, OPC UA12 V DC, 24 V DC, 48 V DC, AC mains
06Zero-trust gatewayGateway that terminates encrypted tunnels, enforces segmentation and gates every flow by identity and policy.EthernetFibre—12 V DC, AC mains
07Fibre terminalOptical network terminal or media converter that lands fibre backhaul at a site.FibreEthernetIEEE 1588 PTP12 V DC, 48 V DC, AC mains

How it scales

01 Instruments Arbitrary qualified sensors and instruments whosemeasurements are ingested with calibration, units,geometry, time, custody and uncertainty. ×n 02 Node The minimum useful deployable unit: server, ruggedappliance, radio node, sensor gateway, satelliteterminal, AI, scientific, vehicle or virtual node. Node Node agent 03 Site The minimum independently operable localgovernance and failure domain: one or more nodesplus local network, identity, policy, evidence,storage, products and operator surfaces.

SITE

Node Node Node ×n 04 Cluster An optional scale or specialisation domain forscheduling, shared storage, accelerators or datalocality.

CLUSTER

×n 05 Fleet Coordinates plans, acknowledgements,convergence evidence, update campaigns andcorrection propagation across nodes and sites.

FLEET

Fleet controller ×n 06 Federation An exchange of products, capabilities, events orwork across approved, independently administeredtrust domains, using explicit trust, policy,data-locality, version and correction contracts.

TRUST DOMAIN

TRUST DOMAIN

TRUST DOMAIN

×n Verifier Applications Data in the field Telemetry Control Data upstream Control Data upstream Control Exchange Evidence Events Exchange
The smallest deployable unit is one node; the same unit is replicated to meet the demand. Nodes form a site, sites may form a cluster, sites and clusters are coordinated as a fleet, and fleets exchange across independently administered trust domains. Each plane is a separate channel with its own open binding.
Data in the field
MQTT 5 with Sparkplug B; connectors for LoRaWAN, OPC UA and instrument buses.
Telemetry
OpenTelemetry OTLP.
Control
TLS 1.3 with mutual authentication; protobuf messages over gRPC or HTTP/2.
Data upstream
At-least-once publication with repeat-safe keys over the control channel or NATS JetStream; QUIC MAY be used on lossy links.
Evidence
DSSE-signed in-toto statements; SLSA provenance; SCITT transparency receipts.
Events
Event envelopes mapped to CloudEvents 1.0; channels described in AsyncAPI 3.
Exchange
OpenAPI 3.1; the OGC API family; SensorThings; STAC; WIS 2.0.

05From order to operation

Every step, from the first call to a running site.

The same crew and the same record carry the work from scope to maintenance.

  1. 01 Order

    Scope with the safety report

    The scope reads the site’s safety report, emissions permit, existing detection and stack monitors, emergency plans and the control system architecture. Nexus Observatory Inc. returns the monitoring design, joins to existing systems, security design and a price per site and per year. 23

  2. 02 Survey

    Survey units and fence lines

    Crews survey units, tank farms, stacks and fence lines with the site’s safety and environment engineers: detector positions for each hazard, camera views, weather station siting and network paths. Hazardous area classifications set what equipment may go where. Findings shape the kit for each site before anything is built. 1

  3. 03 Permits

    Permits to work

    All work follows the site’s permits to work and hot work rules, equipment in hazardous areas is certified for its zone, and connecting monitoring to the network goes through the site’s change control. Every permit is kept with the site record. 5

  4. 04 Build

    Build and certify

    Detectors, cameras and gateways are configured, certified equipment is checked against its zone, nodes are hardened and enrolled with their identities, and the whole system is tested with simulated alarms before it ships. Nothing ships until the whole kit has passed its tests together. 5

  5. 05 Install

    Install during planned work

    Crews install detectors, cameras and the weather station during planned work, connect gateways and the node behind the security gateway, and photograph every point. Existing detectors and stack monitors are joined through their interfaces. Crews follow the site safety plan throughout the work.

  6. 06 Commission

    Commission with gas tests

    Each node proves its identity. Every detector is bump-tested with calibration gas, cameras are checked with a heat source, stack monitor data are compared with the latest quality assurance results, and alarm routes are tested. Acceptance is recorded with the owner before handover. 14

  7. 07 Operate

    One record for safety and permits

    Operators see gas, fire, emissions and weather together. Leaks are found and fixed sooner, emission averages are tracked against limits in real time, and in an incident emergency services receive where the release is heading. Every alert and action is kept on the record. 23

  8. 08 Maintain

    Test, calibrate, report

    Detectors are calibrated and bump-tested on schedule, stack monitors follow their quality assurance cycle, cameras are cleaned and software patched in rings. Annual emissions reports and incident records come from the same signed record. Maintenance history stays with each site for its whole life. 4

06Data products and integration

What it delivers, to whom, and into which systems.

Data products

  • Gas and fire alarms with locationControl rooms and emergency response teams
  • Emission averages against permit limitsEnvironment managers
  • Release direction for incidentsEmergency services
  • Emissions and incident reportsRegulators

Integration

  • Control systemAlarms reach the control room through the site’s own interfaces; monitoring never writes to the control system.
  • Environmental reportingEmission records feed the permit reports.
  • Emergency servicesRelease direction is shared through agreed channels.

Exchanged through OPC UA, Modbus, MQTT.

07Questions buyers ask

Before you scope it.

Does it replace our safety systems?

No. Safety systems stay as they are; this joins monitoring into one record.

Is the equipment certified for hazardous areas?

Yes, for the zone where it is installed.

Can it show where a release goes?

It estimates direction from gas readings and wind.

Is it secure?

The monitoring network is separated and secured to the industrial security series.

08Resources

The sources behind this page.

Public standards, regulations and guidance, cited where they apply. Each applies only where its jurisdiction or scope does.

  1. 1IEC 60079-29-2: Gas detectors, selection, installation, use and maintenance of detectors for flammable gases and oxygenInternational Electrotechnical Commission
  2. 2Directive 2012/18/EU on the control of major-accident hazards involving dangerous substances (Seveso III)European Union · 2012
  3. 3Directive 2010/75/EU on industrial emissionsEuropean Union · 2010
  4. 4EN 14181: Stationary source emissions, quality assurance of automated measuring systemsEuropean Committee for Standardization
  5. 5IEC 62443: Security for industrial automation and control systemsInternational Electrotechnical Commission

09Related

Use cases and solutions.

Use case

Methane fenceline observatory

Point sensors on the fenceline with optical gas imaging and quantification, feeding leak-detection reports.The full use case →
Solution

Mine, plant and port site monitoring

Slope radar, tailings monitoring, dust and water, and site connectivity for operations and closure.Solutions for industry →
Solution

Environmental and permit monitoring

Emissions, water quality, noise and dust monitoring for permit conditions, with traceable calibration and evidence bundles.Solutions for industry →
Solution

Operational-technology assurance for observing sites

Identity, attestation, segmentation and monitoring for instruments and edge nodes, with evidence for audits.Solutions for industry →

10Industry: specialized fields

Other fields of this industry.

Specialized field

Machine condition monitoring

Vibration, temperature and power sensing on pumps, motors, fans, compressors and conveyors, analysed at the edge so maintenance teams fix machines before they fail.The full field →
Specialized field

Factory energy management

Metering of electricity, gas, steam, compressed air and water by line and machine, so factories cut energy use, prove savings and meet energy audit and management duties.The full field →
Specialized field

Workplace dust, noise and heat

Fixed and wearable sensing of dust, gases, noise and heat stress on factory floors, so health and safety teams keep exposure below limits and act where it rises.The full field →

Bring us the site.

Plan a deployment, configure a station, model it in the Studio or talk to sales. The form names who receives your details.

Plan a deploymentStation BuilderOpen the StudioTalk to salesRequest a quote