This site uses strictly necessary cookies to work and to remember your privacy choices. With your permission it would also load content hosted by other services, such as videos, maps and fonts, which then receive your network address and device data. We do not sell or share your personal information and we run no advertising. Choose Accept all, Reject all or Customise. You can change your mind at any time through Privacy choices at the foot of every page.

  • Always on

    Needed for the site to work and to remember your privacy choices. Always on.

  • Remembers settings you choose, such as the light or dark display, in your browser.

  • Loads videos, maps and other content hosted by other services. Those services receive your address and device data.

Menu Close
In this section: Learn
Start
Guides
Domain packs
Participants
Security and privacy
Pilot kits
Operations
Ecosystem

Infrastructure: structural health of bridges, dams, tunnels and buildings

INFORMATIVE Source profiles/domains/infrastructure/pack.yaml

On this page
  1. Observed properties
  2. Recommended quality tests
  3. Bindings and profiles
  4. Scenario: A bridge monitoring system raises a structural alert
  5. Sources
  6. Quality tests: example parameters

Informative: a domain pack is guidance for implementers. It adds no requirement, changes no schema and grants no conformance level. Several of the properties, bindings and profiles it names are proposed by draft proposals.

FieldValue
Statusinformative
Normativeno
Register domainsinfrastructure
Bindingsopcua, sparkplug, lorawan, cap, ogc-api
ProfilesOBSP-NODE, OBSP-SITE, OBSP-GRID, OBSP-CONSUMER
Objects in the scenarioconnector-mapping, connector-output, sensor-passport, calibration-record, observation-record, quality-flag, alert-notice, correction-notice

Informative. This pack is guidance for implementers; it is not part of the specification, adds no requirement and grants no conformance level. The machine-readable form is pack.yaml, checked against ../pack.schema.json by tests/test_domain_packs.py.

Strain, tilt, displacement, vibration and crack sensors, dam seepage and pore pressure, and environmental loads on structures, for condition monitoring and early warning.

Observed properties

Ids from the observed-property register proposed by OIP-0006 (draft). Core: structural_strain_micro, structural_tilt, deflection, crack_width, vibration_acceleration, natural_frequency, pore_water_pressure, dam_seepage_rate. Optional: joint_displacement, cable_tension, bearing_temperature, concrete_internal_temperature, corrosion_rate, peak_particle_velocity, wind_speed, air_temperature, fibre_strain_das, fibre_temperature_dts, traffic_vehicle_count.

Example parameters only; an operator sets its own for each site and sensor and records them in the procedure. The test code is the protocol’s quality-flag test code.

Test Code Properties Unit
gross range RANGE structural_strain_micro um/m
spike SPIKE crack_width mm
rate of change STEP structural_tilt mrad
flat line PERSISTENCE vibration_acceleration m/s2
internal consistency INTERNAL_CONSISTENCY natural_frequency Hz

Bindings and profiles

Bindings (proposed by draft proposals): opcua, sparkplug, lorawan, cap, ogc-api. Profiles: OBSP-NODE, OBSP-SITE, OBSP-GRID, OBSP-CONSUMER.

Scenario: A bridge monitoring system raises a structural alert

Strain gauges, tiltmeters and accelerometers on a bridge report through a data acquisition unit published over Sparkplug, with environmental loads (wind, temperature, traffic). The site cell checks range, spikes and dead channels and computes the temperature-compensated natural frequency. When tilt and frequency both leave their baseline bands, the operator issues a CAP alert scoped to the operator, citing the records, and a correction notice later supersedes one sensor’s values after its re-calibration.

Objects: connector-mapping, connector-output, sensor-passport, calibration-record, observation-record, quality-flag, alert-notice, correction-notice.

Sources

  • ISO 4866, mechanical vibration and shock: vibration of fixed structures (not checked)
  • ISO 16587, mechanical vibration and shock: performance parameters for condition monitoring of structures (not checked)

Sources are cited by identifier only; no text, table or figure is reproduced, and none was checked for this pack.

Quality tests: example parameters

Example parameters only; an operator sets its own for each site and sensor.

TestCodePropertiesUnitExample parametersChecked
gross rangeRANGEobsp:prop:structural_strain_microum/mfailBelow: -3000; failAbove: 3000not checked
spikeSPIKEobsp:prop:crack_widthmmsuspect: 0.2; fail: 1not checked
rate of changeSTEPobsp:prop:structural_tiltmradmaxChangePerHour: 0.5not checked
flat linePERSISTENCEobsp:prop:vibration_accelerationm/s2windowMinutes: 30; tolerance: 0.00001; note: dead accelerometernot checked
internal consistencyINTERNAL_CONSISTENCYobsp:prop:natural_frequencyHzrule: temperature-compensated frequency within the baseline band; maxRelativeDeviation: 0.05not checked