Pipelines and midstream

Pipelines, watched from end to end.

A pipeline crosses rivers, farms, faults and towns, and most of it is buried out of sight. Its operator must know where it leaks, whether its protection against corrosion works and whether the ground around it moves. An observation network along the right-of-way reads pressure and flow, cathodic protection, ground movement and stations, and keeps one record for the control room and the regulator.

Plan a deploymentHow it worksStation Builder
Industry
Energy
Measurements
5
Sources cited
7
  1. Energy · Pipelines and midstream

    Hundreds of kilometres, mostly out of sight

    A pipeline is long, buried and exposed to everything along its route: corrosion, diggers, landslides and rivers. Its control room sees pressure and flow, but integrity depends on what happens between the stations. Observation along the right-of-way fills that gap with readings that are tied to the line itself.

  2. What is measured

    Pressure, protection, ground and activity

    Pressure and flow are read at valve sites; cathodic protection potentials at test posts and rectifiers; ground movement and strain at slopes and crossings; activity on the right-of-way by acoustic sensing and cameras; gas, fire and machine condition at stations. Satellite radar adds the ground between sensors.

    Instruments
    Pressure and flow · Cathodic protection · Slope and strain · Acoustic sensing · Cameras
  3. The base node

    A node at every valve site

    Each valve site’s base node reads instruments through an industrial gateway and hears test-post endpoints through a LoRaWAN gateway. It ties every reading to the line’s stationing, signs it, keeps local trends and raises an alarm on a sudden change in pressure or flow.

  4. Radio and links

    Links along the right-of-way

    LoRaWAN carries test-post and slope readings to valve sites. Satellite or 3GPP non-terrestrial links join remote valve sites to the control room, fibre laid with the pipe serves where it exists, and private networks serve stations and terminals. Each link is chosen per section from the survey.

    Radio
    LoRaWAN · Satellite · Fibre · Private LTE
  5. How it works

    From a test post to the integrity record

    A test post’s potential is read by its endpoint, sent over LoRaWAN to the valve site, tied to stationing and signed by the node, then carried over satellite to the record. There it joins the protection history of that section and raises a flag if protection falls short.

  6. From order to operation · Order

    Scope the line and its risks

    The scope reads the operator’s integrity management plan, high-consequence areas, known geohazards and leak detection approach. Nexus Observatory Inc. returns the sensor plan per section, the radio design along the right-of-way, the integration with the control room and a price per section and per station.

    Plan a deployment
  7. From order to operation · Survey

    Walk the right-of-way

    Crews survey valve sites, test posts, crossings and slopes with the operator’s integrity engineers, measure coverage for LoRaWAN and satellite, confirm power at each site and check landowner access. Every position is recorded against the pipeline’s stationing so data and records line up.

  8. From order to operation · Permits

    Landowners, crossings and the control room

    Work on the right-of-way follows landowner agreements, crossing permits and the operator’s excavation and hot-work rules. Changes that touch the control room follow its management of change, so new alarms reach controllers only after review. Every agreement and approval is kept with the section it covers, so the next crew knows the conditions before arriving.

  9. From order to operation · Build

    Build per site type

    Valve-site stations, test-post endpoints, slope sensors and station kits are built and tested by type, each enrolled with its identity and labelled with its stationing. Gateways are configured with the section they serve, so each reading arrives tied to its place on the line.

    Open the Station Builder
  10. From order to operation · Install

    Install section by section

    Gateways and backhaul go in first, then test-post endpoints, valve-site instruments, slope and crossing sensors and right-of-way cameras. Each installation is checked against the alignment sheets and photographed, and landowners are told what was installed. Gateways at valve sites are mounted inside existing fenced areas wherever possible.

  11. From order to operation · Commission

    Commission against field readings

    Each node proves its identity, then remote cathodic protection readings are compared with a technician’s manual readings, pressure and flow with the control system’s values, and slope sensors with survey. Alarms are tested from the field to the control room console.

  12. From order to operation · Operate

    One line, one picture

    Controllers see pressure, flow and alarms in context; integrity engineers see protection potentials, ground movement and crossing status along the line; station teams see machine condition. Every alarm and response is logged for review against the operator’s procedures. Alarms reach the right person first: controllers for pressure, integrity staff for protection and ground.

  13. From order to operation · Maintain

    Keep the record complete

    Endpoints are serviced on schedule, sensors are added where new geohazards are identified and software moves in rings. The integrity record built from these readings feeds the operator’s inspection planning and its reports, year after year. Endpoints whose readings drift are flagged for a field check before their data is relied on.

    Book field services
  14. Data products

    Products for control, integrity and prevention

    Controllers receive alarms with context; corrosion engineers receive protection records along the line; geotechnical engineers see ground movement at crossings; damage prevention teams receive right-of-way alerts; station teams see machine condition. All are tied to the same stationing and the same signed readings.

    See the data products
  15. Evidence

    An integrity record a regulator can read

    Every reading, alarm, response and change is signed and kept against the pipeline’s stationing. Monitoring follows the operator’s integrity management plan and the pipeline safety rules that apply, so inspectors can follow any conclusion back to the readings and the people who acted on them.

    Drawn against
    49 CFR Parts 192 and 195 · API RP 1130 · CSA Z662 · ISO 15589-1
  16. What you get

    Structural and ground-movement monitoring

    GNSS, InSAR, tilt, strain and fibre sensing on bridges, dams, slopes, tailings and pipelines, with alert thresholds set by the owner. Delivered as managed service and data licence, for infrastructure, mining and pipeline operators, transport agencies. Scale: Asset portfolios. Service levels are written as numbers you can measure on your own dashboard.

    Talk to sales
  17. Next step

    Plan pipelines and midstream with us

    Tell us the site, the measurements and the rules it answers to. We reply with a survey proposal, a design and a scope for pipelines and midstream. An engineer replies with a survey proposal and a scope, and the plan grows from one site to the network you need, at your pace.

    Plan a deploymentOpen the Station BuilderOpen the Studio

01The place and its hazards

Where it runs, and what can go wrong.

Operating contextTransmission and gathering pipelines carry gas and liquids over long distances between producing fields, processing plants, storage and markets, driven by compressor and pump stations. Integrity management covers corrosion, third-party damage, geohazards and leaks. Control rooms watch pressure and flow continuously, and regulations set duties for leak detection, inspection and emergency response.

Hazards

  • Leaks and ruptures from corrosion, cracking or third-party damage
  • Failure of cathodic protection against corrosion
  • Ground movement, landslides and river scour at crossings
  • Unauthorised excavation near the line
  • Fire and gas release at compressor and pump stations

02What must be measured

What, where, how often, and under which rules.

Each measurement names where it is taken, how often, and the public standard or regulation behind it. Numbers in the sources column open the cited source below.

MeasurementWhereCadenceSources
Pressure and flow for leak detectionInlet, outlet and block valve sites along the lineContinuous12
Cathodic protection potentialsTest posts and rectifiers along the lineContinuous remote reads, with surveys on the schedule the rules set34
Ground movement and pipe strainSlopes, faults and river crossings identified as geohazardsContinuous, with satellite radar between stations56
Third-party activity on the right-of-wayHigh-consequence areas, by acoustic sensing, cameras and patrolsContinuous4
Station gas, fire and machine conditionCompressor and pump stationsContinuous7

03The observation stack

From one base unit to a network.

The same blocks at every scale: instruments and a base node, a site with its radio, a fleet run as one, and a network federated on the open protocol.

  1. 01

    Base unit

    A valve-site station: pressure and flow through an industrial gateway, cathodic protection test points on a battery endpoint, and a node that signs and keeps every value.

    Build a station →
  2. 02

    Site

    A section between stations: valve sites, test posts, geohazard sensors and right-of-way cameras, joined by LoRaWAN and satellite to the control room.

    Plan a site →
  3. 03

    Fleet

    Every section and station of the line run as one fleet, with one integrity record and one alarm policy.

    Managed offers →
  4. 04

    Network

    Interconnected systems and the regulator’s reviewers read one federated record, each with the access the agreement gives them.

    The open protocol →
  • 01Flow meter
  • 02Acoustic sensor
  • 03LPWAN endpoint
  • 04LoRaWAN gateway
  • 05OT gateway (OPC UA, Modbus)
  • 06Edge node (Wedge)
  • 073GPP NTN terminal
  • 08Solar array
  • 09Pole

Radio and links

LoRaWAN

Cathodic protection test posts and slope sensors sit every few kilometres with no power; battery endpoints report through gateways at valve sites.

Radio and links

Satellite

Valve sites in remote country reach the control room over satellite or 3GPP non-terrestrial links.

Radio and links

Fibre

Where fibre is laid with the pipe, it carries station data and can also serve as a distributed acoustic sensor.

Radio and links

Private LTE

Around stations and terminals, a private network carries cameras, crew devices and control data.

Edge computeStation and valve-site nodes keep pressure and flow trends locally and raise an alarm on a sudden change, while the control room’s leak detection compares the whole line.

PowerValve sites use station power where available and solar elsewhere; test-post endpoints run on batteries for long periods between visits.

04How it works

From the instrument to the product.

One observation’s path, tier by tier, with the interface on every link and a bill of materials below; then how the one node grows to a site, a fleet and federated networks.

Pipelines and midstream: data path

– of 08

01 Instruments Measurement with sensor identity andcalibration 02 Field radio 03 Gateway 04 Node – Wrap in an observation envelope with timequality– Measure quality and uncertainty, attachquality flags– Buffer locally (store-and-forward when thelink drops) 05 Backhaul Commit with transactional outbox andpublish, delivered at least once 06 Site Consumer inbox deduplicates and applieseach record once into governed data 07 Data store Governed product through API, map orexport, correction-aware 08 Products OPC UA (IEC 62541)DNP3 (IEEE 1815)OGC SensorThings API 09 Power and structure Supplies 12 V DC, 24 V DC, 48 V DC to thefield equipment Cathodic protection test points Not in the reference kit 01 Flow meter SDI-12 · RS-485 · Ethernet 02 Acoustic sensor SDI-12 · RS-485 · Ethernet 03 LPWAN endpoint Analogue I/O · SDI-12 · RS-485 04 LoRaWAN gateway Ethernet · RF · GNSS antenna 05 OT gateway (OPC UA, Modbus) Ethernet · RS-485 · CAN · AnalogueI/O 06 Edge node (Wedge) Ethernet · Fibre · USB · RS-485 ·BMC 07 3GPP NTN terminal Ethernet · USB · RS-232 Site MQTT 5 with Sparkplug B Governed data store Versioned, correction-aware Leak and pressure alarmswith context Cathodic protection recordsalong the line Geohazard and crossingmonitoring Right-of-way activity alerts Station condition records 08 Solar array RS-485 09 Pole Analogue I/O RS-485 · Modbus Ethernet LoRaWAN Ethernet Ethernet · opc-ua Ethernet 3GPP NTN
From the instrument to the published product: each band is a tier, each connector names its interface, and the numbers match the bill of materials. Hover or focus a block to trace its path; scroll or step to follow one observation.
Bill of materials
ItemEquipmentData portsProtocolsPower in
01Flow meterOpen-channel or pipe flow meter (Doppler, ultrasonic, electromagnetic).SDI-12RS-485EthernetSDI-12, Modbus, MQTT 5, OGC SensorThings API12 V DC
02Acoustic sensorSound level meter, acoustic event detector or infrasound array element.SDI-12RS-485EthernetSDI-12, Modbus, MQTT 5, OGC SensorThings API12 V DC
03LPWAN endpointBattery-powered endpoint on LoRaWAN, NB-IoT or LTE-M that carries one or more sensors.Analogue I/OSDI-12RS-485LoRaWAN, OMA LwM2M, CoAPInternal battery, Energy harvesting
04LoRaWAN gatewayMulti-channel LoRaWAN gateway that forwards uplinks to a network server and schedules downlinks within duty limits.EthernetRFGNSS antennaLoRaWAN, MQTT 5PoE, 12 V DC
05OT gateway (OPC UA, Modbus)Read-only bridge from industrial fieldbuses and controllers (Modbus, OPC UA, DNP3, IEC 61850, CAN) to the site network, behind a security boundary.EthernetRS-485CANAnalogue I/OOPC UA, Modbus, DNP3 (IEEE 1815), IEC 61850 (MMS, GOOSE), MQTT 524 V DC
06Edge node (Wedge)Rugged edge node that boots from signed media, attests itself and establishes a site cell from little or no infrastructure.EthernetFibreUSBRS-485BMCMQTT 5, DMTF Redfish, IEEE 1588 PTP, NTP with NTS, OPC UA12 V DC, 24 V DC, 48 V DC, AC mains
073GPP NTN terminalTerminal using the 3GPP non-terrestrial network air interface (NR-NTN or IoT-NTN) to reach a satellite access node directly.EthernetUSBRS-2323GPP NR or IoT NTN, OMA LwM2M, MQTT 512 V DC, Internal battery
08Solar arrayPV modules with charge controller sized to the site’s load and climate.RS-485Modbus—
09PoleUtility, street or dedicated pole with clamp positions.———

How it scales

01 Instruments Arbitrary qualified sensors and instruments whosemeasurements are ingested with calibration, units,geometry, time, custody and uncertainty. ×n 02 Node The minimum useful deployable unit: server, ruggedappliance, radio node, sensor gateway, satelliteterminal, AI, scientific, vehicle or virtual node. Node Node agent 03 Site The minimum independently operable localgovernance and failure domain: one or more nodesplus local network, identity, policy, evidence,storage, products and operator surfaces.

SITE

Node Node Node ×n 04 Cluster An optional scale or specialisation domain forscheduling, shared storage, accelerators or datalocality.

CLUSTER

×n 05 Fleet Coordinates plans, acknowledgements,convergence evidence, update campaigns andcorrection propagation across nodes and sites.

FLEET

Fleet controller ×n 06 Federation An exchange of products, capabilities, events orwork across approved, independently administeredtrust domains, using explicit trust, policy,data-locality, version and correction contracts.

TRUST DOMAIN

TRUST DOMAIN

TRUST DOMAIN

×n Verifier Applications Data in the field Telemetry Control Data upstream Control Data upstream Control Exchange Evidence Events Exchange
The smallest deployable unit is one node; the same unit is replicated to meet the demand. Nodes form a site, sites may form a cluster, sites and clusters are coordinated as a fleet, and fleets exchange across independently administered trust domains. Each plane is a separate channel with its own open binding.
Data in the field
MQTT 5 with Sparkplug B; connectors for LoRaWAN, OPC UA and instrument buses.
Telemetry
OpenTelemetry OTLP.
Control
TLS 1.3 with mutual authentication; protobuf messages over gRPC or HTTP/2.
Data upstream
At-least-once publication with repeat-safe keys over the control channel or NATS JetStream; QUIC MAY be used on lossy links.
Evidence
DSSE-signed in-toto statements; SLSA provenance; SCITT transparency receipts.
Events
Event envelopes mapped to CloudEvents 1.0; channels described in AsyncAPI 3.
Exchange
OpenAPI 3.1; the OGC API family; SensorThings; STAC; WIS 2.0.

05From order to operation

Every step, from the first call to a running site.

The same crew and the same record carry the work from scope to maintenance.

  1. 01 Order

    Scope the line and its risks

    The scope reads the operator’s integrity management plan, high-consequence areas, known geohazards and leak detection approach. Nexus Observatory Inc. returns the sensor plan per section, the radio design along the right-of-way, the integration with the control room and a price per section and per station. 45

  2. 02 Survey

    Walk the right-of-way

    Crews survey valve sites, test posts, crossings and slopes with the operator’s integrity engineers, measure coverage for LoRaWAN and satellite, confirm power at each site and check landowner access. Every position is recorded against the pipeline’s stationing so data and records line up.

  3. 03 Permits

    Landowners, crossings and the control room

    Work on the right-of-way follows landowner agreements, crossing permits and the operator’s excavation and hot-work rules. Changes that touch the control room follow its management of change, so new alarms reach controllers only after review. Every agreement and approval is kept with the section it covers, so the next crew knows the conditions before arriving.

  4. 04 Build

    Build per site type

    Valve-site stations, test-post endpoints, slope sensors and station kits are built and tested by type, each enrolled with its identity and labelled with its stationing. Gateways are configured with the section they serve, so each reading arrives tied to its place on the line.

  5. 05 Install

    Install section by section

    Gateways and backhaul go in first, then test-post endpoints, valve-site instruments, slope and crossing sensors and right-of-way cameras. Each installation is checked against the alignment sheets and photographed, and landowners are told what was installed. Gateways at valve sites are mounted inside existing fenced areas wherever possible.

  6. 06 Commission

    Commission against field readings

    Each node proves its identity, then remote cathodic protection readings are compared with a technician’s manual readings, pressure and flow with the control system’s values, and slope sensors with survey. Alarms are tested from the field to the control room console.

  7. 07 Operate

    One line, one picture

    Controllers see pressure, flow and alarms in context; integrity engineers see protection potentials, ground movement and crossing status along the line; station teams see machine condition. Every alarm and response is logged for review against the operator’s procedures. Alarms reach the right person first: controllers for pressure, integrity staff for protection and ground.

  8. 08 Maintain

    Keep the record complete

    Endpoints are serviced on schedule, sensors are added where new geohazards are identified and software moves in rings. The integrity record built from these readings feeds the operator’s inspection planning and its reports, year after year. Endpoints whose readings drift are flagged for a field check before their data is relied on.

06Data products and integration

What it delivers, to whom, and into which systems.

Data products

  • Leak and pressure alarms with contextControl room controllers
  • Cathodic protection records along the lineCorrosion and integrity engineers, regulators
  • Geohazard and crossing monitoringIntegrity and geotechnical engineers
  • Right-of-way activity alertsDamage prevention teams
  • Station condition recordsStation maintenance teams

Integration

  • Pipeline SCADA and leak detectionField data arrives through industrial gateways over OPC UA and DNP3 alongside the control system’s own points.
  • Integrity management and GISReadings are tied to pipeline stationing and delivered as layers in the operator’s GIS.
  • Damage preventionRight-of-way alerts reach the one-call and patrol workflows.

Exchanged through OPC UA (IEC 62541), DNP3 (IEEE 1815), OGC SensorThings API.

07Questions buyers ask

Before you scope it.

Does this replace our leak detection system?

No. It adds field data and alarms beside the control room’s leak detection, which remains the system of record.

Can remote cathodic protection reads replace annual surveys?

Remote reads add continuous data between surveys; whether they replace any survey depends on the rules that apply to the line.

How are geohazards found between sensors?

Satellite radar interferometry covers the line between ground sensors and flags movement for a closer look.

Can we start with high-consequence areas?

Yes. Most programmes start with high-consequence areas and known geohazards, then extend along the line.

08Resources

The sources behind this page.

Public standards, regulations and guidance, cited where they apply. Each applies only where its jurisdiction or scope does.

  1. 1API RP 1130: Computational Pipeline Monitoring for LiquidsAmerican Petroleum Institute
  2. 249 CFR Part 195: Transportation of hazardous liquids by pipelineUS Pipeline and Hazardous Materials Safety Administration (eCFR)
  3. 3ISO 15589-1: Cathodic protection of pipeline systems, on-land pipelinesInternational Organization for Standardization
  4. 449 CFR Part 192: Transportation of natural and other gas by pipelineUS Pipeline and Hazardous Materials Safety Administration (eCFR)
  5. 5CSA Z662: Oil and gas pipeline systemsCSA Group
  6. 6Copernicus Sentinel-1 radar missionEuropean Space Agency
  7. 7ISO 20816: Mechanical vibration, measurement and evaluation of machine vibrationInternational Organization for Standardization

09Related

Use cases and solutions.

Solution

Structural and ground-movement monitoring

GNSS, InSAR, tilt, strain and fibre sensing on bridges, dams, slopes, tailings and pipelines, with alert thresholds set by the owner.Solutions for energy →
Solution

Transport and logistics corridor sensing

Road weather, rail condition, port and cold-chain sensing along corridors, with connectivity where coverage ends.Solutions for energy →
Solution

Satellite and non-terrestrial backhaul

LEO and GEO backhaul, 3GPP non-terrestrial integration and direct-to-device fallbacks for remote sites.Solutions for energy →

10Energy: specialized fields

Other fields of this industry.

Specialized field

Upstream oil and gas

Methane detection and quantification at wellpads and facilities, flare and tank monitoring, wellhead flow and pressure, on satellite and private links for sites with no one on them.The full field →
Specialized field

Thermal power plants

Continuous emissions, machine condition, cooling water and plant weather for gas, coal and biomass plants, with an industrial network that keeps the control system separate and secure.The full field →
Specialized field

Hydropower and dams

Dam safety instruments, reservoir and river levels, inflow forecasting and downstream warning, with links that keep working in the flood the dam is there to hold.The full field →
Specialized field

Wind farms

Wind resource and power performance, turbine condition, icing, lightning and wildlife monitoring, from the first met mast to an operating farm on one record.The full field →
Specialized field

Solar power plants

Irradiance, module temperature, soiling, inverter output and plant weather to international monitoring classes, for bankable performance ratios and fewer surprises in operation.The full field →
Specialized field

Transmission networks

Line ratings from measured weather and conductor state, wildfire and vegetation watch, substation automation and synchrophasor timing, on private LTE, microwave and fibre along the corridor.The full field →
Specialized field

Distribution networks and the grid edge

Feeder and transformer monitoring, distributed energy resources, fault location and outage evidence, on a utility private network that reaches every pole and substation.The full field →

Bring us the site.

Plan a deployment, configure a station, model it in the Studio or talk to sales. The form names who receives your details.

Plan a deploymentStation BuilderOpen the StudioTalk to salesRequest a quote