Skip to content

Observatory ProtocolSpecificationFunctions

From first contact to retirement, function by function.

Join, Admit, Describe, Time, Observe, Qualify, Federate, Orchestrate, Correct, Exchange, Prove, and Exit. Each function names the objects it moves, the participants it involves and the open standards it is drawn against.

Version
0.1.0-draft
Status
Draft specification
Specification
CC BY 4.0
Code
Apache-2.0
Steward
GCRI Canada
Source
obsp-0.1-foundation

The practice this part continues.

1881–1884Coordinated campaigns
The International Polar Year, inspired by Karl Weyprecht, took place from 1881 to 1884 as a series of coordinated international expeditions to the polar regions. It established that comparable measurement across sites is a matter of agreed method before it is a matter of instruments. [1]
WMOGlobal observing as a system
The World Meteorological Organization’s Global Observing System collects weather, climate, water and environmental data from satellites and surface stations, and is now part of WIGOS, the overarching framework for all WMO observing systems. WIS 2.0 carries the exchange of those data onto open standards and Web technologies. The protocol treats these frameworks as the reference for describing stations and publishing their data. [2][3][4]
FederationsNetworks of networks
The International Federation of Digital Seismograph Networks unites the groups responsible for installing and maintaining seismographs in their own regions. The International GNSS Service has provided open access to high-quality GNSS data products since 1994, giving access to the global reference frame, the ITRF. Each shows that a federation keeps local ownership and still yields one coherent record. The protocol’s rule of one owner per fact, and its federation function, follow that model. [5][6][7]
TimeA shared clock
Coordinated Universal Time is computed by the BIPM from data contributed by timing laboratories. IEEE 1588 defines the Precision Time Protocol, and ITU-T G.8275.1 profiles it for phase and time synchronisation across networks. In the protocol, time is a function in its own right: a measurement whose clock cannot be trusted cannot be published as trusted. [8][9][10]
2013–2016Provenance and reuse
The W3C PROV documents (2013) define an interchange model for provenance. The FAIR Guiding Principles (2016) ask that data be findable, accessible, interoperable and reusable. The protocol attaches provenance, uncertainty, quality and correction state to every value, so that reuse never strips the conditions of measurement. [11][12]
2023Attested identity
The IETF RATS architecture (RFC 9334) describes how one party appraises evidence about the state of another. The protocol’s Join and Admit functions apply that model to instruments: a participant begins untrusted and is admitted on evidence, not on assertion. [13]

From first contact to retirement, function by function.

Select a function to read its requirements, the objects it moves, the participants it involves and the standards behind it.

  • Join A node proves what it is, receives an identity and a policy, then a signed plan.
  • Admit Providers enter by manifest, rights, security and technical review, for a stated scope.
  • Describe Every instrument and observation carries what, where, how and by whom.
  • Time One time base across the grid, with time quality as explicit state.
  • Observe Streams and files move over whatever link the site has, with store and forward.
  • Qualify Quality flags, calibration and provenance travel with each value.
  • Federate Nodes form cells, cells form clusters, and clusters federate across trust domains.
  • Orchestrate Software, configuration and upgrades roll out by signed plan, with evidence for every change.
  • Correct An upstream correction marks dependants stale, triggers recompute and publishes a new version.
  • Exchange Governed products reach people and applications through versioned APIs, events, maps and exports.
  • Prove Peers answer unpredictable challenges and emit signed proof receipts for an independent verifier.
  • Exit and decommission Every material provider has an open export and replacement path, and decommissioning closes the record.

Each function as a plate.

One axonometric scene for each function: a physical part and the record it produces. The tabs are the twelve functions; the explorer above says the same in words.

Join Select a function to see its scene.

One set of functions across observing domains.

Observing and technology domains, and the functions on which each relies.

  • Satellite and non-terrestrial links Admit, Time, Observe, Federate.
  • Ground stations and terminals Admit, Describe, Observe, Qualify.
  • Radio access network Admit, Time, Qualify, Orchestrate.
  • AI-RAN shared compute Admit, Time, Qualify, Orchestrate.
  • 5G core and edge computing Join, Admit, Federate, Orchestrate.
  • Positioning, navigation and timing Time, Qualify, Join.
  • Edge hardware and runtime Join, Admit, Orchestrate, Federate.
  • AI models and agents Admit, Qualify, Orchestrate.
  • Earth observation Describe, Observe, Qualify, Exchange.
  • GIS, maps and twins Describe, Qualify, Exchange, Correct.
  • Sensors and instruments Describe, Time, Observe, Qualify.
  • IoT and low-power wireless Join, Admit, Observe, Orchestrate.
  • Power and energy Observe, Orchestrate.
  • Security, identity and supply chain Join, Admit, Orchestrate, Prove.
  • Data, pipelines and exchange Describe, Observe, Qualify, Correct, Exchange.
  • Field deployment and operations Join, Observe, Qualify, Exit and decommission.

Read it, test it, propose a change.

The Observatory Protocol is an open specification. Any party may implement it, and every change is proposed and decided in public.

References

Sources for the historical and standards statements on this page.

  1. NOAA Pacific Marine Environmental Laboratory. "The First International Polar Year: History." www.pmel.noaa.gov/arctic-zone/ipy-1/History.htm
  2. World Meteorological Organization. "Global Observing System (GOS)." community.wmo.int/en/activity-areas/global-observing-system-gos
  3. World Meteorological Organization. "WMO Integrated Global Observing System (WIGOS)." community.wmo.int/en/activity-areas/wigos
  4. World Meteorological Organization. "WMO Information System (WIS) and WIS 2.0." community.wmo.int/en/activity-areas/wis
  5. International Federation of Digital Seismograph Networks. "About the FDSN." www.fdsn.org/about/
  6. International GNSS Service. "About the IGS." igs.org/about/
  7. IGN, ITRF Product Center. "International Terrestrial Reference Frame." itrf.ign.fr/en/homepage
  8. Bureau International des Poids et Mesures. "Realizing and disseminating international reference time scales: UTC, UTCr and TT(BIPM)." www.bipm.org/en/time-ftp
  9. IEEE Std 1588-2019. "IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems." doi.org/10.1109/IEEESTD.2020.9120376
  10. ITU-T Recommendation G.8275.1. "Precision time protocol telecom profile for phase/time synchronization with full timing support from the network." www.itu.int/rec/T-REC-G.8275.1
  11. W3C (2013). "PROV-Overview: An Overview of the PROV Family of Documents." W3C Working Group Note, 30 April 2013. www.w3.org/TR/prov-overview/
  12. Wilkinson, M. D., et al. (2016). "The FAIR Guiding Principles for scientific data management and stewardship." Scientific Data 3, 160018. doi.org/10.1038/sdata.2016.18
  13. Birkholz, H., et al. (2023). RFC 9334, "Remote ATtestation procedureS (RATS) Architecture." IETF. www.rfc-editor.org/rfc/rfc9334
  14. Bradner, S. (1997). RFC 2119, "Key words for use in RFCs to Indicate Requirement Levels." IETF. www.rfc-editor.org/rfc/rfc2119
  15. Leiba, B. (2017). RFC 8174, "Ambiguity of Uppercase vs Lowercase in RFC 2119 Key Words." IETF. www.rfc-editor.org/rfc/rfc8174