Choose what this site may use

This site uses strictly necessary cookies to work and to remember your privacy choices. With your permission it would also load content hosted by other services, such as videos, maps and fonts, which then receive your network address and device data. We do not sell or share your personal information and we run no advertising. Choose Accept all, Reject all or Customise. You can change your mind at any time through Privacy choices at the foot of every page.

  • Always on

    Needed for the site to work and to remember your privacy choices. Always on.

  • Remembers settings you choose, such as the light or dark display, in your browser.

  • Loads videos, maps and other content hosted by other services. Those services receive your address and device data.

Menu Close
In this section: Proposals
Proposals
Drafts
Proposed registers

OIP-0019: Field connector bindings: LoRaWAN, OPC UA, WIS 2.0 and BUFR ingest, NMEA 0183 and SDI-12

DRAFT Source oips/drafts/OIP-0019/OIP-0019.md

On this page
  1. Summary
  2. Requirements
  3. Patches
  4. Proposal text
  5. Draft folder
FieldValue
StatusDRAFT
Functionobserve (§5.5); no new function (the register keeps exactly twelve). A connector is part of Observe
Affects§5.5 (one bullet naming the field connector bindings, no new key word); new bindings bindings/lorawan/, bindings/opcua/, bindings/wis2-ingest/, bindings/nmea/, bindings/sdi12/ with their tests and a shared test helper; registers/relations.yaml (new rows EXT-LORAWAN, EXT-OPCUA, EXT-WMOBUFR, EXT-NMEA, EXT-SDI12); registers/implements-edges.json and registers/requirements.yaml regenerated; new cases CT-NODE-080 to CT-NODE-084 (automated: the golden examples of each binding replayed, obsp.golden) with replay evidence in the OBSP-NODE example sets and the invariant module sdk/python/src/obsp/inv_oip0019.py; the demo-binding helper of tests/test_validate.py made independent of the shipped bindings
RequiresOIP-0007 (connector contract CON-1 to CON-10, schemas connector-mapping and connector-output), with the two enum additions of "Amendments asked of OIP-0007" below. The patches apply to the current tree on their own; the acceptance order is below
Last call30 days (bindings of an existing function, no new object) unless the editors rule otherwise
Texton this page · OIP-0019.md · README.md

Summary

Section 5.5 says a node "MAY also speak LoRaWAN, OPC UA or vendor buses through a connector", and OIP-0007 states what every connector must do (CON-1 to CON-10) with one worked binding, Sparkplug. The field technologies most stations use besides Sparkplug have no binding: LoRaWAN sensors behind a network server, OPC…

Requirements

  • BND-LORAWAN-01 to -13
  • BND-OPCUA-01 to -13
  • BND-WIS2INGEST-01 to -12
  • BND-NMEA-01 to -13
  • BND-SDI12-01 to -13

Patches

The edits acceptance would apply. They are in the protocol repository at the pinned commit and are not served on this site.

FileSize (bytes)
patches/bindings-common.patch15141
patches/bindings-lorawan.patch68397
patches/bindings-nmea.patch58633
patches/bindings-opcua.patch81083
patches/bindings-sdi12.patch54952
patches/bindings-wis2-ingest.patch85528
patches/cases.patch33527
patches/registers.patch5577
patches/spec.patch1062

Proposal text

Field Value
Status DRAFT
Function observe (§5.5); no new function (the register keeps exactly twelve). A connector is part of Observe
Requires OIP-0007 (connector contract CON-1 to CON-10, schemas connector-mapping and connector-output), with the two enum additions of “Amendments asked of OIP-0007” below. The patches apply to the current tree on their own; the acceptance order is below
Uses OIP-0006 (observed-property register): every mapped property id and every BUFR descriptor is one its register patch names; the binding tests check it against registers/observed-properties.yaml once that register exists
Affects §5.5 (one bullet naming the field connector bindings, no new key word); new bindings bindings/lorawan/, bindings/opcua/, bindings/wis2-ingest/, bindings/nmea/, bindings/sdi12/ with their tests and a shared test helper; registers/relations.yaml (new rows EXT-LORAWAN, EXT-OPCUA, EXT-WMOBUFR, EXT-NMEA, EXT-SDI12); registers/implements-edges.json and registers/requirements.yaml regenerated; new cases CT-NODE-080 to CT-NODE-084 (automated: the golden examples of each binding replayed, obsp.golden) with replay evidence in the OBSP-NODE example sets and the invariant module sdk/python/src/obsp/inv_oip0019.py; the demo-binding helper of tests/test_validate.py made independent of the shipped bindings
Protocol version obsp/0.1
Last call 30 days (bindings of an existing function, no new object) unless the editors rule otherwise

Problem

Section 5.5 says a node “MAY also speak LoRaWAN, OPC UA or vendor buses through a connector”, and OIP-0007 states what every connector must do (CON-1 to CON-10) with one worked binding, Sparkplug. The field technologies most stations use besides Sparkplug have no binding: LoRaWAN sensors behind a network server, OPC UA servers in plants and utilities, WMO stations that report in BUFR through WIS 2.0, marine and buoy instruments speaking NMEA 0183, and hydrological and agricultural sensors on an SDI-12 bus. Without a binding, two connectors for the same technology can take different native identifiers as identity (a LoRaWAN DevAddr that changes every session, an OPC UA namespace index a server may renumber, a WIGOS identifier built from block and station numbers), read a server clock as the observation time, flag a value good because the instrument said “valid”, ignore a checksum or a CRC, shift SDI-12 values by one position, or fill a frame counter gap silently. A consumer cannot compare their outputs and a verifier cannot replay them.

Change

Normative text (§5.5, one bullet after “Field-side transport”)

  • Field connector bindings: bindings/lorawan/ (LoRaWAN uplinks from a network server), bindings/opcua/ (OPC UA, IEC 62541, PubSub and client reads), bindings/wis2-ingest/ (WMO BUFR announced by WIS 2.0), bindings/nmea/ (NMEA 0183) and bindings/sdi12/ (SDI-12) fix the connector mapping for each technology; a connector that names one of them in its mapping is held to every requirement of that binding’s profile.

The bullet carries no key word, so the requirement index keeps its ids; the binding requirements are the normative content. §6 is not edited: its Data (field) row already names connectors for LoRaWAN, OPC UA and vendor buses, and OIP-0001, OIP-0005 and OIP-0009 edit the lines around it.

The five bindings (status proposed)

Each folder follows bindings/README.md and the Sparkplug binding of OIP-0007: PROFILE.md (scope, standard, every requirement, the mapping table by clause, examples, open questions), binding.yaml, mapping.yaml (every row with its clause and checked: not checked, the decoder described as data, elements not mapped with the reason), connector-mapping.json (a connector-mapping record whose decoderDigest is the SHA-256 of the canonical JSON form of the decoder tables and whose goldens list every example with its digest), positive and negative golden examples (the native message rendered as JSON, the connector’s state before it, and the expected output as a projection), and a test.

Binding Standard (edition) Native id (scheme) Quality Time source Sequence Requirements Examples (+/-)
lorawan LoRaWAN L2 1.0.4 (2020), LoRaWAN 1.1 (2017) DevEUI (LORAWAN_DEVEUI) none: NOT_CHECKED NETWORK_SERVER (receive time) FCnt, modulo 2^32 per device, reset at a new session BND-LORAWAN-01 to -13 5 / 5
opcua IEC 62541 parts 3, 4, 6, 8, 14 (2020 or later) server URI and object NodeId with namespace URI (OPCUA_NODEID) StatusCode severity: Good, Uncertain, Bad DEVICE (SourceTimestamp) PubSub DataSetMessage sequence number, modulo 2^16; client read none BND-OPCUA-01 to -13 4 / 5
wis2-ingest WMO FM 94 BUFR edition 4 (WMO-No. 306), WIGOS identifier (WMO-No. 1160), WIS2 Notification Message (WMO-No. 1061) WIGOS station identifier from the subset (WIGOS_STATION_ID) quality control indication 033020 (WMO_BUFR_QC) DEVICE (subset time) none BND-WIS2INGEST-01 to -12 4 / 4
nmea NMEA 0183 4.11 (IEC 61162-1:2016); NMEA 2000 named only port and talker (NMEA_SOURCE) status field A or V (NMEA_STATUS) CONNECTOR (receive time) none BND-NMEA-01 to -13 7 / 4
sdi12 SDI-12 1.4 bus and address (SDI12_ADDRESS) none: NOT_CHECKED GATEWAY (datalogger) none BND-SDI12-01 to -13 5 / 4

What each binding pins down beyond the contract:

  • LoRaWAN: identity by DevEUI, never DevAddr; FPort 0 and 224 to 255 never converted; payload decoders are byte layouts described as data (offset, type, scale, decimals, no-data sentinel); a no-data sentinel is MISSING; a repeated FCnt (retransmission) gives nothing; gateway EUI, RSSI, SNR and gateway time and the radio parameters are link evidence, never a result time; the MIC is the network server’s.
  • OPC UA: identity by ExpandedNodeId with nsu=, never ns=<index>; variables by BrowseName under the instrument object; DataValue Value to result by a data type table, an absent Value is MISSING; StatusCode severity Good, Uncertain, Bad to GOOD, SUSPECT, BAD (reserved severity never GOOD); SourceTimestamp only, never ServerTimestamp; EngineeringUnits by a UNECE common code to UCUM table (21 units), a unit other than the mapped one gives no observation; no Write or Call.
  • WIS 2.0 and BUFR ingest: identity from descriptors 001125 to 001128 of the subset, never the notification alone and never built from block and station numbers; the retrieved bytes must have the announced digest before decoding; descriptors to properties only by the table (each descriptor is the WMO code of its property in the OIP-0006 register patch: 012101, 012103, 013003, 010004, 010051, 011001, 011002, 011041), converted from the Table B unit (K to Cel, Pa to hPa) and rounded to the table’s decimals; quality from 033020 by table; time from 004001 to 004006; one output per subset. It is the inbound counterpart of bindings/wis2/ (OIP-0009, exchange) and does not overlap it.
  • NMEA 0183: identity <port>/<talker>; the checksum is checked and recorded as raw evidence (CON-7), a sentence that fails it gives nothing else; native fields carry their unit or reference letter (MWV.speed.N) and each letter has its own conversion; an MWV angle, measured from the bow, is never a direction from north; GGA gives a trajectory point (obsp.trajectory), never usable at fix quality 0; ZDA gives a clock sample (obsp.time); NMEA 2000 parameter groups are listed only.
  • SDI-12: identity <bus>/<address>, converted only when the identification response matches the mapping’s (an address is reused when a sensor is replaced); the k-th value across the data pages is native field M.k (M1.k, C.k), mapped by position from the sensor metadata; an announced value not delivered is MISSING; a data page that fails its CRC gives nothing; the datalogger clock stamps the measurement.

Amendments asked of OIP-0007

The connector-mapping schema of OIP-0007 has closed lists (its open question 7 says further native id schemes each need an OIP). This proposal is that OIP for two of them and for two quality schemes:

List in connector-mapping.schema.json Addition
$defs/NativeId/properties/scheme/enum NMEA_SOURCE (<port>/<talker>), SDI12_ADDRESS (<bus>/<address>, address one of 0-9, A-Z, a-z)
$defs/QualityMap/properties/scheme/enum WMO_BUFR_QC (code table 0 33 020), NMEA_STATUS (status field A or V)

Because the schema is not in the tree, these additions cannot be a patch of this proposal that applies on its own. They are applied to OIP-0007’s schema when OIP-0007 is accepted (if this proposal is accepted with it) or by a one-line patch at this proposal’s acceptance; tests/connector_golden.py states them (AMENDMENT) and validates every connector mapping against the OIP-0007 schema with them as soon as the schema exists. Nothing else in OIP-0007 changes: the bindings use only its time sources, sequence schemes, unmapped reasons and the namespaced extensions bag (obsp.trajectory, obsp.time on outputs, obsp.sdi12 on a mapping).

Registers

  • registers/relations.yaml: five new external rows, each naming its binding folder in artefacts, function observe, profile OBSP-NODE and schemas observation-record and time-quality (the schemas in the tree today). No existing row states these standards, so extending one was not possible.
  • registers/implements-edges.json regenerated (46 edges); registers/requirements.yaml regenerated (the §5.5 requirements gain the five cases; the new bullet has no key word, so no id changes).

Acceptance order

  1. OIP-0007 is accepted first (its schemas, cases CT-NODE-071 to CT-NODE-075 and Sparkplug binding), with the amendments above in its connector-mapping schema.
  2. This proposal’s patches are applied together. Then, in the same change: connector-mapping and connector-output join schemas of each binding.yaml and of the five relation rows; python3 tools/build_edges.py and python3 tools/requirements.py are run again; the binding tests then also validate each connector mapping against the schema (they skip that check today).
  3. When OIP-0006 is accepted, the tests check every mapped property and descriptor against the register (they skip that check today).

Compatibility

Additive: five bindings, five relation rows, five automated cases, one non-normative bullet. No existing document changes meaning and no schema changes in this proposal. The OBSP-NODE example set gains five replay evidence documents (the digests of the golden outputs) and the OBSP-NODE negative set gains the same five, so that it still fails only the two cases it was built to fail. tests/test_validate.py checks the demo binding alone, so it no longer depends on how many bindings ship (the same hunk as OIP-0009’s).

Tests

Requirement Case Kind
BND-LORAWAN-01 to -13 CT-NODE-080 automated: replay of every golden uplink (binding-replay-lorawan); tests/test_lorawan_binding.py
BND-OPCUA-01 to -13 CT-NODE-081 automated: replay of every golden example (binding-replay-opcua); tests/test_opcua_binding.py
BND-WIS2INGEST-01 to -12 CT-NODE-082 automated: replay of every golden example (binding-replay-wis2-ingest); tests/test_wis2_ingest_binding.py
BND-NMEA-01 to -13 CT-NODE-083 automated: replay of every golden example (binding-replay-nmea); tests/test_nmea_binding.py
BND-SDI12-01 to -13 CT-NODE-084 automated: replay of every golden example (binding-replay-sdi12); tests/test_sdi12_binding.py

The case numbers 080 to 084 follow OIP-0007’s 071 to 075 and leave 076 to 079 free. Each binding test derives every positive example’s expected output from its native message and the binding’s tables, shows that each negative example breaks exactly the requirement its file name states (and only that one), checks the decoder digest against the decoder tables and the golden digests against the files, checks each connector mapping structurally against the OIP-0007 contract with the amendments, and has binding-specific checks (frame counter wrap, unknown source, OPC UA unit ids against the common code encoding, StatusCode severity, NMEA checksum, SDI-12 CRC and value order).

Negative examples, one broken requirement each: LoRaWAN devaddr-as-identity (-01), no-data-sentinel-as-value (-05), frame-counter-gap-not-recorded (-06), repeated-frame-counter-recorded (-07), gateway-time-as-result-time (-08); OPC UA namespace-index-identity (-01), uncertain-as-good (-06), server-timestamp-as-result-time (-07), unit-mismatch-converted (-08), sequence-gap-not-recorded (-09); WIS 2.0 and BUFR traditional-id-as-wigos (-01), integrity-mismatch-accepted (-03), kelvin-not-converted (-05), qc-doubtful-as-good (-07); NMEA checksum-ignored (-03), knots-not-converted (-05), relative-angle-as-direction (-06), void-status-as-good (-08); SDI-12 identity-mismatch-accepted (-03), values-shifted (-04), missing-value-as-zero (-07), crc-ignored (-08).

Open questions

  1. Every clause number, code, field order and unit code in the five bindings is checked: not checked against the published texts (LoRaWAN 1.0.4 and 1.1, IEC 62541 parts, WMO-No. 306, 1160 and 1061, NMEA 0183 4.11 and IEC 61162-1, SDI-12 1.4, UNECE Recommendation 20). A person must compare them before any binding leaves proposed status.
  2. Unmapped reasons: OIP-0007 has NOT_IN_MAPPING, TRANSIENT and UNSUPPORTED_TYPE. OPC UA uses NOT_IN_MAPPING for a unit that differs from the mapped one and UNSUPPORTED_TYPE for a value without a source timestamp; LoRaWAN uses UNSUPPORTED_TYPE for a payload of the wrong length. Should OIP-0007 add UNIT_MISMATCH, NO_TIME and LENGTH_MISMATCH?
  3. Source-declared quality: NMEA status A and OPC UA Good map to GOOD, as Sparkplug quality 192 does in OIP-0007. Should a flag that only repeats what the source declares be GOOD, or NOT_CHECKED with the native code kept, until a protocol test has run (OIP-0007 open question 3)?
  4. Payload digests where the connector sees no bytes: the OPC UA binding digests a canonical JSON form of the DataValues and the SDI-12 binding the response lines with their line ends. Is a canonical form acceptable raw evidence under CON-7?
  5. Should byte layouts (LoRaWAN), descriptor tables (BUFR) and unit tables (OPC UA) become registers with digests, so that two operators can show they decode the same way, instead of living in each binding’s mapping.yaml?
  6. The WIS 2.0 ingest binding reads instantaneous values only; accumulated and extreme values need the interval form of the universal observation (OIP-0006). Should the period descriptors wait for it?
  7. Should the connector cases move to an optional connector overlay instead of OBSP-NODE (OIP-0007 open question 5)? A node that speaks one of these technologies natively has no connector.

Acceptance needs appointed editors and a last-call window. Until then this proposal stays at DRAFT and none of the five bindings exists in the protocol.

Draft folder

The proposal and, under patches/, the exact edits acceptance would make. Nothing here changes the protocol until the editors accept the proposal and its patches are applied in the same change. The proposal requires OIP-0007; the patches are made against the current tree and apply to it on their own (acceptance order in the proposal).

File What it changes on acceptance
OIP-0019.md the proposal
patches/spec.patch §5.5: one bullet after “Field-side transport” naming the five field connector bindings (no key word, so no requirement id changes)
patches/bindings-common.patch tests/connector_golden.py (the checks the five binding tests share: the OIP-0007 contract checked structurally with this proposal’s enum additions, schema and register checks once those exist, golden digests, the derive and break harness) and the demo-binding helper of tests/test_validate.py made independent of the shipped bindings
patches/bindings-lorawan.patch bindings/lorawan/ (profile, manifest, mapping.yaml with the byte layouts, connector-mapping.json, five positive and five negative examples), tests/test_lorawan_binding.py
patches/bindings-opcua.patch bindings/opcua/ (profile, manifest, mapping.yaml with the data type, severity and UNECE-to-UCUM unit tables, connector-mapping.pubsub.json, connector-mapping.read.json, four positive and five negative examples), tests/test_opcua_binding.py
patches/bindings-wis2-ingest.patch bindings/wis2-ingest/ (profile, manifest, mapping.yaml with the descriptor and quality tables, connector-mapping.json, four positive and four negative examples), tests/test_wis2_ingest_binding.py
patches/bindings-nmea.patch bindings/nmea/ (profile, manifest, mapping.yaml with the sentence and field tables and the NMEA 2000 parameter groups, connector-mapping.json, seven positive and four negative examples), tests/test_nmea_binding.py
patches/bindings-sdi12.patch bindings/sdi12/ (profile, manifest, mapping.yaml with the command table, connector-mapping.json, five positive and four negative examples), tests/test_sdi12_binding.py
patches/registers.patch relations.yaml: new rows EXT-LORAWAN, EXT-OPCUA, EXT-WMOBUFR, EXT-NMEA, EXT-SDI12 at the end of external; implements-edges.json regenerated (46 edges); requirements.yaml regenerated (the §5.5 requirements gain the five cases)
patches/cases.patch cases CT-NODE-080 to CT-NODE-084, one per binding, changed from manual to automated (kind invariant): sdk/python/src/obsp/inv_oip0019.py registers binding-replay-<id> (obsp.golden.replay: the implementer supplies the digest of the output its connector produced for each golden example, and the suite compares it with the golden output; a negative example must not give its claimed output), hooked in conformance.py; replay evidence for the five bindings in the OBSP-NODE example set and its negative set; sdk/python/tests/test_inv_oip0019.py. The attestations of the manual form are gone

Apply all nine patches together (in any order): the registers name the binding folders, the bindings name the cases, and the binding tests need the shared helper. Acceptance removes patches/.

Overlaps with other drafts (each proposal applies on its own; whichever is accepted second resolves these): registers.patch regenerates implements-edges.json (the count line) as OIP-0005, OIP-0006, OIP-0008 and OIP-0009 do, and appends to the end of relations.yaml as OIP-0005 does: append the rows and run python3 tools/build_edges.py and python3 tools/requirements.py. The tests/test_validate.py hunk of bindings-common.patch is the same text as OIP-0009’s (bindings-wis2.patch); the second one drops it. The spec bullet sits on lines no other draft touches.

Check that every patch still applies to the current tree: python3 -m unittest tests.test_validate -k draft_patches.

What stays manual

Nothing of the five cases is left to attestation. One clause is not shown by documents and is not checked by the suite: that an OPC UA client writes nothing to the server (CT-NODE-081; a read-only client has no output to compare). The replay checks the connector on the golden inputs only; behaviour on other inputs is not tested.