Skip to content
Nexus Observatory

/

Civil resilience

/

Specialized fields

/

Critical site security

Unstaffed critical sites, guarded in the physical and the digital.

Substations, pumping stations, telecom hubs and observing sites run unstaffed. Their fences, doors and control networks are where physical and cyber attacks begin. Perimeter sensing, intrusion alarms and passive watch over the control network report to one record, so operators respond before service is lost.

Plan a deploymentHow it worksStation Builder
Industry
Civil resilience
Measurements
5
Sources cited
5
  1. Civil resilience · Critical site security

    Where attacks begin

    Unstaffed substations, pumping stations and telecom hubs keep a country running, and their fences, doors and control networks are where physical and cyber attacks begin. Operators of essential services must manage both risks and report incidents. Knowing the moment a fence is crossed or a strange device appears changes the outcome.

  2. What is measured

    Perimeter, doors and the network

    Radar and thermal cameras watch fence lines and approaches day and night, fixed cameras cover each detection zone, contacts watch doors, gates and cabinets, and a passive tap listens to the site control network for new devices and unusual traffic without ever sending into it.

    Instruments
    Radar · Thermal cameras · Fixed cameras · Door contacts · Passive network tap
  3. The base node

    Verified before it is raised

    The site node fuses radar, thermal and video so animals and weather do not raise alarms, and attaches a clip to every alarm it does raise. It learns the normal devices and traffic of the control network and flags anything new, signing every event for the incident record.

  4. Radio and links

    Two paths, one guarded

    Alarms and clips ride the operator’s fibre to the control room through a security gateway that keeps the monitoring separate from the control network. A cellular path on another network keeps alarms flowing when the fibre is cut, often an intruder’s first move.

    Links
    Fibre · Public cellular
  5. How it works

    From a cut fence to a response

    At night radar picks up a person approaching a substation fence. The thermal camera confirms it, the node raises a verified alarm with a clip, and security operations sends responders and alerts the police. Control engineers check the network view: no new device has appeared.

  6. From order to operation · Order

    Scope the sites and the threats

    The scope reads the operator’s site list, its risk assessment under the critical entity rules, past incidents, the control system architecture and its response arrangements. Nexus Observatory Inc. returns a kit by site type, the alarm and verification design, the network monitoring design and a price per site and per year.

    Plan a deployment
  7. From order to operation · Survey

    Survey perimeters and networks

    Crews walk each site type with the operator’s security and control engineers: fence lines and approaches, detection zones and camera positions, entry points, the control network layout, tap points and the two backhaul paths. Findings are recorded with photographs and drawings.

  8. From order to operation · Permits

    Access, privacy and change control

    Work in substations follows the operator’s switching and access rules, cameras are aimed and masked to follow privacy rules for public land, and connecting a tap to the control network goes through the operator’s change control. Every approval is kept with the site record.

  9. From order to operation · Build

    Build and harden

    Kits are built per site type; nodes are hardened, enrolled with their identities and configured with the zones and alarm rules. The whole kit is tested together, including a simulated intrusion and an unknown device on a test control network, before it ships.

    Open the Station Builder
  10. From order to operation · Install

    Install without an outage

    Crews install radar and cameras on poles, contacts on doors and cabinets and the passive tap on the control network without interrupting it. Power and backhaul are connected, and every point is photographed and recorded. Crews follow the site safety plan throughout the work.

  11. From order to operation · Commission

    Commission with a walk test

    Each node proves its identity. A walk test crosses every detection zone at different speeds, doors and cabinets are opened, alarms are verified in the control room and the network baseline is learned over weeks before anomaly alerts are enabled.

  12. From order to operation · Operate

    Respond with evidence

    The security operations view shows every site, its alarms, verified clips and network anomalies. Responders are sent only to verified events, control engineers see unknown devices at once, and every incident is recorded for reporting to the authorities. Every alert and action is kept on the record.

  13. From order to operation · Maintain

    Test, patch and review

    Detection zones are walk-tested on the agreed plan, cameras are cleaned and re-aimed, node software is patched in rings, and network baselines are reviewed after every planned change. Incident reviews feed back into zones and rules, and every change is kept with the site record.

    Book field services
  14. Data products

    For security, control and compliance

    Security operations and responders receive verified alarms with clips; control system engineers receive new device and traffic alerts; resilience and compliance teams receive incident records; executives and regulators receive site risk and response reports, each tied to the site and time.

    See the data products
  15. Evidence

    Records the rules ask for

    Measures support the critical entity resilience directive and the cybersecurity directive. Intrusion detection follows the alarm system standard, video follows the surveillance standard, and control network monitoring follows the industrial automation security series. Every alarm, clip and response is signed and kept.

    Drawn against
    Directive (EU) 2022/2557 · Directive (EU) 2022/2555 · EN 50131 · IEC 62676 · IEC 62443
  16. What you get

    Operational-technology assurance for observing sites

    Identity, attestation, segmentation and monitoring for instruments and edge nodes, with evidence for audits. Stated as services, never as a security guarantee. Delivered as managed service and professional services, for operators of critical sites, agencies. Scale: Fleets of sites. Service levels are written as numbers you can measure on your own dashboard.

    Talk to sales
  17. Next step

    Plan critical site security with us

    Tell us the site, the measurements and the rules it answers to. We reply with a survey proposal, a design and a scope for critical site security. An engineer replies with a survey proposal and a scope, and the plan grows from one site to the network you need, at your pace.

    Plan a deploymentOpen the Station BuilderOpen the Studio

01The place and its hazards

Where it runs, and what can go wrong.

Operating contextOperators of essential services must manage physical and cyber risks to the sites that deliver them. Critical entities are required to take resilience measures and report incidents, network and information systems must meet cybersecurity duties, industrial control systems are secured to the international series for automation security, and alarm and video systems follow their own standards.

Hazards

  • Fence cutting and break-ins at unstaffed sites
  • Theft of copper, batteries and fuel
  • Unauthorised devices on the control network
  • Remote access that bypasses the operator’s controls
  • Alarms that flood a control room with false triggers

02What must be measured

What, where, how often, and under which rules.

Each measurement names where it is taken, how often, and the public standard or regulation behind it. Numbers in the sources column open the cited source below.

MeasurementWhereCadenceSources
Perimeter intrusionFences and approaches, by radar and thermal camerasContinuous, events on detection12
Door, cabinet and gate stateEvery entry point and control cabinetOn event1
Video verification of alarmsCameras covering each detection zoneOn event, with recorded clips3
Control network traffic and new devicesA passive tap on the site control networkContinuous45
Incidents and response timesEvery alarm from detection to closureEvery event25

03The observation stack

From one base unit to a network.

The same blocks at every scale: instruments and a base node, a site with its radio, a fleet run as one, and a network federated on the open protocol.

  1. 01

    Base unit

    A site point: radar, thermal and fixed cameras, door and cabinet contacts and a passive network tap on an edge node.

    Build a station →
  2. 02

    Site

    A site: the node behind a security gateway, two backhaul paths and its own protected power.

    Plan a site →
  3. 03

    Fleet

    Every unstaffed site of an operator watched from one security operations view, with one incident record.

    Managed offers →
  4. 04

    Network

    Operators share incident records with authorities and sector bodies under the critical entity and cybersecurity rules.

    The open protocol →
  • 01Thermal camera
  • 02Fixed camera
  • 03Surveillance radar (FMCW)
  • 04Edge node (Wedge)
  • 05Zero-trust gateway
  • 06Fibre terminal
  • 07Cellular modem/router
  • 08Pole

Radio and links

Fibre

Most substations and pumping stations have operator fibre; alarms and clips ride it to the control room.

Radio and links

Public cellular

A cellular path on another network keeps alarms flowing when the fibre is cut, often the first thing an intruder does.

Edge computeThe node fuses radar, thermal and video so animals and weather do not raise alarms, verifies every alarm with a clip, learns the normal devices and traffic on the control network and flags anything new, and signs every event.

PowerThe security node runs from the site’s protected DC supply with its own battery, so it keeps reporting when an intruder cuts the mains.

04How it works

From the instrument to the product.

One observation’s path, tier by tier, with the interface on every link and a bill of materials below; then how the one node grows to a site, a fleet and federated networks.

Critical site security: data path

– of 07

01 Instruments Measurement with sensor identity andcalibration 02 Node – Wrap in an observation envelope with timequality– Measure quality and uncertainty, attachquality flags– Buffer locally (store-and-forward when thelink drops) 03 Local network 04 Backhaul Commit with transactional outbox andpublish, delivered at least once 05 Site Consumer inbox deduplicates and applieseach record once into governed data 06 Data store Governed product through API, map orexport, correction-aware 07 Products ONVIFMQTTSyslog 08 Power and structure 01 Thermal camera Ethernet 02 Fixed camera Ethernet 03 Surveillance radar(FMCW) Ethernet Passive tap on the sitecontrol network Not in the reference kit Door, gate and cabinetcontacts Not in the reference kit 04 Edge node (Wedge) Ethernet · Fibre · USB · RS-485 ·BMC 05 Zero-trust gateway Ethernet · Fibre 06 Fibre terminal Fibre · Ethernet 07 Cellular modem/router Ethernet · USB · RS-232 Site MQTT 5 with Sparkplug B Governed data store Versioned, correction-aware Verified intrusion alarms with clips New device and traffic alerts Incident records Site risk and response reports 08 Pole Ethernet · RTSP/ONVIF Ethernet · RTSP/ONVIF Ethernet · MQTT 5 Ethernet RS-485 Ethernet Fibre Ethernet Fibre LTE/NR
From the instrument to the published product: each band is a tier, each connector names its interface, and the numbers match the bill of materials. Hover or focus a block to trace its path; scroll or step to follow one observation.
Bill of materials
ItemEquipmentData portsProtocolsPower in
01Thermal cameraLong-wave infrared camera for fire detection, equipment hot spots and night monitoring.EthernetRTSP with ONVIF profiles, MQTT 5PoE
02Fixed cameraFixed visible-light camera for site security, scene monitoring and machine vision.EthernetRTSP with ONVIF profiles, MQTT 5PoE
03Surveillance radar (FMCW)Short-range FMCW radar for perimeter, traffic, drone and water-surface detection.EthernetMQTT 5, OGC SensorThings API12 V DC
04Edge node (Wedge)Rugged edge node that boots from signed media, attests itself and establishes a site cell from little or no infrastructure.EthernetFibreUSBRS-485BMCMQTT 5, DMTF Redfish, IEEE 1588 PTP, NTP with NTS, OPC UA12 V DC, 24 V DC, 48 V DC, AC mains
05Zero-trust gatewayGateway that terminates encrypted tunnels, enforces segmentation and gates every flow by identity and policy.EthernetFibre—12 V DC, AC mains
06Fibre terminalOptical network terminal or media converter that lands fibre backhaul at a site.FibreEthernetIEEE 1588 PTP12 V DC, 48 V DC, AC mains
07Cellular modem/routerLTE or NR modem or router that uses a public carrier or private network as backhaul.EthernetUSBRS-2323GPP E-UTRA air interface, 3GPP NR air interface, OMA LwM2M12 V DC, PoE
08PoleUtility, street or dedicated pole with clamp positions.———

How it scales

01 Instruments Arbitrary qualified sensors and instruments whosemeasurements are ingested with calibration, units,geometry, time, custody and uncertainty. ×n 02 Node The minimum useful deployable unit: server, ruggedappliance, radio node, sensor gateway, satelliteterminal, AI, scientific, vehicle or virtual node. Node Node agent 03 Site The minimum independently operable localgovernance and failure domain: one or more nodesplus local network, identity, policy, evidence,storage, products and operator surfaces.

SITE

Node Node Node ×n 04 Cluster An optional scale or specialisation domain forscheduling, shared storage, accelerators or datalocality.

CLUSTER

×n 05 Fleet Coordinates plans, acknowledgements,convergence evidence, update campaigns andcorrection propagation across nodes and sites.

FLEET

Fleet controller ×n 06 Federation An exchange of products, capabilities, events orwork across approved, independently administeredtrust domains, using explicit trust, policy,data-locality, version and correction contracts.

TRUST DOMAIN

TRUST DOMAIN

TRUST DOMAIN

×n Verifier Applications Data in the field Telemetry Control Data upstream Control Data upstream Control Exchange Evidence Events Exchange
The smallest deployable unit is one node; the same unit is replicated to meet the demand. Nodes form a site, sites may form a cluster, sites and clusters are coordinated as a fleet, and fleets exchange across independently administered trust domains. Each plane is a separate channel with its own open binding.
Data in the field
MQTT 5 with Sparkplug B; connectors for LoRaWAN, OPC UA and instrument buses.
Telemetry
OpenTelemetry OTLP.
Control
TLS 1.3 with mutual authentication; protobuf messages over gRPC or HTTP/2.
Data upstream
At-least-once publication with repeat-safe keys over the control channel or NATS JetStream; QUIC MAY be used on lossy links.
Evidence
DSSE-signed in-toto statements; SLSA provenance; SCITT transparency receipts.
Events
Event envelopes mapped to CloudEvents 1.0; channels described in AsyncAPI 3.
Exchange
OpenAPI 3.1; the OGC API family; SensorThings; STAC; WIS 2.0.

05From order to operation

Every step, from the first call to a running site.

The same crew and the same record carry the work from scope to maintenance.

  1. 01 Order

    Scope the sites and the threats

    The scope reads the operator’s site list, its risk assessment under the critical entity rules, past incidents, the control system architecture and its response arrangements. Nexus Observatory Inc. returns a kit by site type, the alarm and verification design, the network monitoring design and a price per site and per year. 2

  2. 02 Survey

    Survey perimeters and networks

    Crews walk each site type with the operator’s security and control engineers: fence lines and approaches, detection zones and camera positions, entry points, the control network layout, tap points and the two backhaul paths. Findings are recorded with photographs and drawings. 4

  3. 03 Permits

    Access, privacy and change control

    Work in substations follows the operator’s switching and access rules, cameras are aimed and masked to follow privacy rules for public land, and connecting a tap to the control network goes through the operator’s change control. Every approval is kept with the site record.

  4. 04 Build

    Build and harden

    Kits are built per site type; nodes are hardened, enrolled with their identities and configured with the zones and alarm rules. The whole kit is tested together, including a simulated intrusion and an unknown device on a test control network, before it ships. 4

  5. 05 Install

    Install without an outage

    Crews install radar and cameras on poles, contacts on doors and cabinets and the passive tap on the control network without interrupting it. Power and backhaul are connected, and every point is photographed and recorded. Crews follow the site safety plan throughout the work.

  6. 06 Commission

    Commission with a walk test

    Each node proves its identity. A walk test crosses every detection zone at different speeds, doors and cabinets are opened, alarms are verified in the control room and the network baseline is learned over weeks before anomaly alerts are enabled. 1

  7. 07 Operate

    Respond with evidence

    The security operations view shows every site, its alarms, verified clips and network anomalies. Responders are sent only to verified events, control engineers see unknown devices at once, and every incident is recorded for reporting to the authorities. Every alert and action is kept on the record. 5

  8. 08 Maintain

    Test, patch and review

    Detection zones are walk-tested on the agreed plan, cameras are cleaned and re-aimed, node software is patched in rings, and network baselines are reviewed after every planned change. Incident reviews feed back into zones and rules, and every change is kept with the site record.

06Data products and integration

What it delivers, to whom, and into which systems.

Data products

  • Verified intrusion alarms with clipsSecurity operations and responders
  • New device and traffic alertsControl system engineers
  • Incident recordsResilience and compliance teams
  • Site risk and response reportsExecutives and regulators

Integration

  • Security operationsVerified alarms reach the operator’s alarm receiving platform through its own interfaces.
  • Control systemNetwork anomalies are sent to the operator’s security monitoring, never into the control system itself.
  • Incident reportingRecords are exported for notification to the competent authorities.

Exchanged through ONVIF, MQTT, Syslog.

07Questions buyers ask

Before you scope it.

Does the tap touch our control system?

It is passive: it listens and never sends into the control network.

Will animals set off alarms?

Radar, thermal and video are fused so most animals and weather are filtered.

Does it help with reporting duties?

Yes. Incident records hold what authorities ask for.

Can it run if the fibre is cut?

Yes. Alarms switch to a cellular path on another network.

08Resources

The sources behind this page.

Public standards, regulations and guidance, cited where they apply. Each applies only where its jurisdiction or scope does.

  1. 1EN 50131: Alarm systems, intrusion and hold-up systemsEuropean Committee for Electrotechnical Standardization
  2. 2Directive (EU) 2022/2557 on the resilience of critical entitiesEuropean Union · 2022
  3. 3IEC 62676: Video surveillance systems for use in security applicationsInternational Electrotechnical Commission
  4. 4IEC 62443: Security for industrial automation and control systemsInternational Electrotechnical Commission
  5. 5Directive (EU) 2022/2555 on measures for a high common level of cybersecurity across the UnionEuropean Union · 2022

09Related

Use cases and solutions.

Solution

Operational-technology assurance for observing sites

Identity, attestation, segmentation and monitoring for instruments and edge nodes, with evidence for audits.Solutions for civil resilience →
Solution

Structural and ground-movement monitoring

GNSS, InSAR, tilt, strain and fibre sensing on bridges, dams, slopes, tailings and pipelines, with alert thresholds set by the owner.Solutions for civil resilience →
Solution

Power-grid edge and right-of-way monitoring

Line temperature and sag, vegetation encroachment from EO and LiDAR, substation sensors and fire-weather at the right-of-way.Solutions for civil resilience →

10Civil resilience: specialized fields

Other fields of this industry.

Specialized field

Timing integrity

Time references with holdover and monitoring for grids, telecom and finance, so a country’s critical systems keep accurate time when satellite signals are jammed, spoofed or lost.The full field →
Specialized field

Backup power at critical sites

Generators, fuel, batteries and transfer switches at hospitals, water plants and telecom hubs, monitored and tested so backup power starts when the grid fails.The full field →
Specialized field

Northern and Arctic observing

Weather, permafrost, ground movement and river and lake ice stations for northern civil authorities, built for polar night, deep cold and satellite-only backhaul.The full field →

Bring us the site.

Plan a deployment, configure a station, model it in the Studio or talk to sales. The form names who receives your details.

Plan a deploymentStation BuilderOpen the StudioTalk to salesRequest a quote