Skip to content
Nexus Observatory

/

Health

/

Specialized fields

/

Wastewater surveillance

A community’s health, read in its wastewater.

Wastewater carries signals of infection days before people seek care, from the whole community and anonymously. Flow-proportional samplers, flow meters and water quality sensors at treatment plants and in sewers make those samples comparable, and give laboratories and public health the context they need.

Plan a deploymentHow it worksStation Builder
Industry
Health
Measurements
4
Sources cited
3
  1. Health · Wastewater surveillance

    Signals before symptoms

    Wastewater carries signals of infection days before people seek care, from the whole community and anonymously. Guidance now recommends wastewater surveillance and the recast wastewater directive includes it, but results only compare across days and places when samples are flow-proportional and normalised.

  2. What is measured

    Flow, samples and quality

    Flow meters at treatment plant inlets and sewer points measure flow continuously, autosamplers take flow-proportional composites, and water quality sensors at each point record the context laboratories need to normalise results, such as dilution after rain. Each reading carries its time and its quality flags.

    Instruments
    Flow meters · Autosamplers · Water quality sensors
  3. The base node

    Comparable samples

    The node drives flow-proportional sampling, records each composite’s flow and quality, flags rain dilution and sampler faults, and sends sample metadata ahead of the laboratory result, so public health can read rises with confidence. Nothing is lost when a link drops; the node keeps it.

  4. Radio and links

    From sewer to surveillance

    Sampling points send flow, quality and sampler state over cellular, and sewer points away from power report over a low-power link. Metadata reach laboratory and public health systems with each sample. Each link is chosen for the place, not from a catalogue.

    Links
    Public cellular · LoRaWAN
  5. How it works

    From a rising signal to early action

    Over a week, normalised signals rise in two catchments while clinical cases are flat. Public health issues local advice and readies clinics; cases climb a few days later in exactly those areas, and services are already prepared. Every step is kept on the record.

  6. From order to operation · Order

    Scope the programme

    The scope reads the programme’s plants, catchments, laboratories and reporting duties. Nexus Observatory Inc. returns the sampling design, metadata flow and a price per point and per year. Every assumption in the scope is written down and priced. The scope is agreed before any site work begins.

    Plan a deployment
  7. From order to operation · Survey

    Survey sampling points

    Crews survey plant inlets and sewer points with operators: flow measurement, sampler access, safety in confined spaces, power and coverage. Findings are recorded with drawings. Every finding is kept with the site record for the crews who follow. Findings shape the kit for each site before anything is built.

  8. From order to operation · Permits

    Utility and safety approval

    Utilities approve equipment at their plants and sewers, confined space rules govern sewer work, and data sharing with public health is agreed. Every approval is kept with the point record. Approvals are tracked site by site, so nothing waits unseen.

  9. From order to operation · Build

    Build and test

    Samplers, flow meters and sensors are configured, gateways and the node set up for flow-proportional sampling and enrolled with their identities, and the chain is tested on the bench. Test results travel with the kit to the site. Nothing ships until the whole kit has passed its tests together.

    Open the Station Builder
  10. From order to operation · Install

    Install at inlets and sewers

    Crews install samplers, flow meters and sensors at inlets and sewer points under confined space rules, connect gateways, power and backhaul, and record every point. The site record is updated before the crew leaves. Crews follow the site safety plan throughout the work.

  11. From order to operation · Commission

    Commission with parallel samples

    Each node proves its identity. Flow is checked against plant meters, composites against manual parallel samples, and metadata reach the laboratory and public health systems. Results are signed and kept with the site record. Acceptance is recorded with the owner before handover.

  12. From order to operation · Operate

    Read the community

    Public health receives normalised results with flow and quality context, sees trends by catchment, and acts on rises days before clinical cases climb. Every sample keeps its chain of custody. Reports for owners and funders come from the same record.

  13. From order to operation · Maintain

    Service and audit

    Samplers are cleaned and serviced, flow meters verified, sensors recalibrated and software updated in rings. Chain of custody records are audited, and every change is kept with the point record. Spares and procedures travel with the crews. Maintenance history stays with each site for its whole life.

    Book field services
  14. Data products

    For public health and laboratories

    Public health agencies receive normalised wastewater signals; laboratories receive sample metadata; utility operators receive sampler and flow alerts; health and environment authorities receive programme reports, each tied to catchment, sample and date. Each product carries its site, time and quality flags.

    See the data products
  15. Evidence

    Guidance and the directive

    Sampling follows the European recommendation on wastewater surveillance and the recast urban wastewater directive, and international guidance on environmental surveillance. Every sample keeps its flow, quality and chain of custody record. Records are open to the people who must check them.

    Drawn against
    Commission Recommendation (EU) 2021/472 · Directive (EU) 2024/3019 · Environmental surveillance for SARS-CoV-2 to complement public health surveillance
  16. What you get

    Environmental and permit monitoring

    Emissions, water quality, noise and dust monitoring for permit conditions, with traceable calibration and evidence bundles. Delivered as managed service and data licence, for industrial operators, municipalities, regulators. Scale: Site to portfolio. Service levels are written as numbers you can measure on your own dashboard.

    Talk to sales
  17. Next step

    Plan wastewater surveillance with us

    Tell us the site, the measurements and the rules it answers to. We reply with a survey proposal, a design and a scope for wastewater surveillance. An engineer replies with a survey proposal and a scope, and the plan grows from one site to the network you need, at your pace.

    Plan a deploymentOpen the Station BuilderOpen the Studio

01The place and its hazards

Where it runs, and what can go wrong.

Operating contextWastewater surveillance for public health is recommended in European guidance and now included in the recast urban wastewater directive, and international guidance sets how environmental surveillance complements case surveillance. Results are only comparable when samples are flow-proportional and normalised.

Hazards

  • Samples not proportional to flow
  • Rain diluting signals
  • Samplers failing silently
  • Results without flow or quality context
  • Slow paths from sample to public health

02What must be measured

What, where, how often, and under which rules.

Each measurement names where it is taken, how often, and the public standard or regulation behind it. Numbers in the sources column open the cited source below.

MeasurementWhereCadenceSources
FlowTreatment plant inlets and sewer pointsContinuous12
Flow-proportional composite samplingAutosamplers at inlets and sewer pointsDaily composites on schedule13
Water quality for normalisationSensors at sampling pointsContinuous3
Sample chain of custodyFrom sampler to laboratoryEach sample1

03The observation stack

From one base unit to a network.

The same blocks at every scale: instruments and a base node, a site with its radio, a fleet run as one, and a network federated on the open protocol.

  1. 01

    Base unit

    A sampling point: an autosampler, flow meter and water quality sensors on an industrial gateway.

    Build a station →
  2. 02

    Site

    A plant or catchment: sampling points at the inlet and in sewers, with an edge node.

    Plan a site →
  3. 03

    Fleet

    A national programme’s plants on one surveillance view.

    Managed offers →
  4. 04

    Network

    Programmes share results and metadata with public health and international surveillance.

    The open protocol →
  • 01Flow meter
  • 02Water quality sonde
  • 03OT gateway (OPC UA, Modbus)
  • 04Edge node (Wedge)
  • 05Cellular modem/router

Radio and links

Public cellular

Sampling points send flow, quality and sampler state over cellular.

Radio and links

LoRaWAN

Sewer points away from power report flow and level over a low-power link.

Edge computeThe node drives flow-proportional sampling, records each composite’s flow and quality, flags rain dilution and sampler faults, and sends sample metadata ahead of the laboratory result.

PowerPlant points run from plant power; sewer points from batteries or small solar panels.

04How it works

From the instrument to the product.

One observation’s path, tier by tier, with the interface on every link and a bill of materials below; then how the one node grows to a site, a fleet and federated networks.

Wastewater surveillance: data path

– of 07

01 Instruments Measurement with sensor identity andcalibration 02 Gateway 03 Node – Wrap in an observation envelope with timequality– Measure quality and uncertainty, attachquality flags– Buffer locally (store-and-forward when thelink drops) 04 Backhaul Commit with transactional outbox andpublish, delivered at least once 05 Site Consumer inbox deduplicates and applieseach record once into governed data 06 Data store Governed product through API, map orexport, correction-aware 07 Products OPC UAOGC SensorThings APIHL7 FHIR 01 Flow meter SDI-12 · RS-485 · Ethernet 02 Water quality sonde SDI-12 · RS-485 · Ethernet Refrigerated flow-proportionalautosampler Not in the reference kit 03 OT gateway (OPC UA, Modbus) Ethernet · RS-485 · CAN · AnalogueI/O 04 Edge node (Wedge) Ethernet · Fibre · USB · RS-485 ·BMC 05 Cellular modem/router Ethernet · USB · RS-232 Site MQTT 5 with Sparkplug B Governed data store Versioned, correction-aware Normalised wastewater signals Sample metadata Sampler and flow alerts Programme reports RS-485 · Modbus RS-485 · Modbus RS-485 Ethernet · opc-ua Ethernet LTE/NR
From the instrument to the published product: each band is a tier, each connector names its interface, and the numbers match the bill of materials. Hover or focus a block to trace its path; scroll or step to follow one observation.
Bill of materials
ItemEquipmentData portsProtocolsPower in
01Flow meterOpen-channel or pipe flow meter (Doppler, ultrasonic, electromagnetic).SDI-12RS-485EthernetSDI-12, Modbus, MQTT 5, OGC SensorThings API12 V DC
02Water quality sondeMulti-parameter sonde for temperature, conductivity, pH, dissolved oxygen and turbidity.SDI-12RS-485EthernetSDI-12, Modbus, MQTT 5, OGC SensorThings API12 V DC
03OT gateway (OPC UA, Modbus)Read-only bridge from industrial fieldbuses and controllers (Modbus, OPC UA, DNP3, IEC 61850, CAN) to the site network, behind a security boundary.EthernetRS-485CANAnalogue I/OOPC UA, Modbus, DNP3 (IEEE 1815), IEC 61850 (MMS, GOOSE), MQTT 524 V DC
04Edge node (Wedge)Rugged edge node that boots from signed media, attests itself and establishes a site cell from little or no infrastructure.EthernetFibreUSBRS-485BMCMQTT 5, DMTF Redfish, IEEE 1588 PTP, NTP with NTS, OPC UA12 V DC, 24 V DC, 48 V DC, AC mains
05Cellular modem/routerLTE or NR modem or router that uses a public carrier or private network as backhaul.EthernetUSBRS-2323GPP E-UTRA air interface, 3GPP NR air interface, OMA LwM2M12 V DC, PoE

How it scales

01 Instruments Arbitrary qualified sensors and instruments whosemeasurements are ingested with calibration, units,geometry, time, custody and uncertainty. ×n 02 Node The minimum useful deployable unit: server, ruggedappliance, radio node, sensor gateway, satelliteterminal, AI, scientific, vehicle or virtual node. Node Node agent 03 Site The minimum independently operable localgovernance and failure domain: one or more nodesplus local network, identity, policy, evidence,storage, products and operator surfaces.

SITE

Node Node Node ×n 04 Cluster An optional scale or specialisation domain forscheduling, shared storage, accelerators or datalocality.

CLUSTER

×n 05 Fleet Coordinates plans, acknowledgements,convergence evidence, update campaigns andcorrection propagation across nodes and sites.

FLEET

Fleet controller ×n 06 Federation An exchange of products, capabilities, events orwork across approved, independently administeredtrust domains, using explicit trust, policy,data-locality, version and correction contracts.

TRUST DOMAIN

TRUST DOMAIN

TRUST DOMAIN

×n Verifier Applications Data in the field Telemetry Control Data upstream Control Data upstream Control Exchange Evidence Events Exchange
The smallest deployable unit is one node; the same unit is replicated to meet the demand. Nodes form a site, sites may form a cluster, sites and clusters are coordinated as a fleet, and fleets exchange across independently administered trust domains. Each plane is a separate channel with its own open binding.
Data in the field
MQTT 5 with Sparkplug B; connectors for LoRaWAN, OPC UA and instrument buses.
Telemetry
OpenTelemetry OTLP.
Control
TLS 1.3 with mutual authentication; protobuf messages over gRPC or HTTP/2.
Data upstream
At-least-once publication with repeat-safe keys over the control channel or NATS JetStream; QUIC MAY be used on lossy links.
Evidence
DSSE-signed in-toto statements; SLSA provenance; SCITT transparency receipts.
Events
Event envelopes mapped to CloudEvents 1.0; channels described in AsyncAPI 3.
Exchange
OpenAPI 3.1; the OGC API family; SensorThings; STAC; WIS 2.0.

05From order to operation

Every step, from the first call to a running site.

The same crew and the same record carry the work from scope to maintenance.

  1. 01 Order

    Scope the programme

    The scope reads the programme’s plants, catchments, laboratories and reporting duties. Nexus Observatory Inc. returns the sampling design, metadata flow and a price per point and per year. Every assumption in the scope is written down and priced. The scope is agreed before any site work begins. 12

  2. 02 Survey

    Survey sampling points

    Crews survey plant inlets and sewer points with operators: flow measurement, sampler access, safety in confined spaces, power and coverage. Findings are recorded with drawings. Every finding is kept with the site record for the crews who follow. Findings shape the kit for each site before anything is built.

  3. 03 Permits

    Utility and safety approval

    Utilities approve equipment at their plants and sewers, confined space rules govern sewer work, and data sharing with public health is agreed. Every approval is kept with the point record. Approvals are tracked site by site, so nothing waits unseen.

  4. 04 Build

    Build and test

    Samplers, flow meters and sensors are configured, gateways and the node set up for flow-proportional sampling and enrolled with their identities, and the chain is tested on the bench. Test results travel with the kit to the site. Nothing ships until the whole kit has passed its tests together.

  5. 05 Install

    Install at inlets and sewers

    Crews install samplers, flow meters and sensors at inlets and sewer points under confined space rules, connect gateways, power and backhaul, and record every point. The site record is updated before the crew leaves. Crews follow the site safety plan throughout the work.

  6. 06 Commission

    Commission with parallel samples

    Each node proves its identity. Flow is checked against plant meters, composites against manual parallel samples, and metadata reach the laboratory and public health systems. Results are signed and kept with the site record. Acceptance is recorded with the owner before handover. 13

  7. 07 Operate

    Read the community

    Public health receives normalised results with flow and quality context, sees trends by catchment, and acts on rises days before clinical cases climb. Every sample keeps its chain of custody. Reports for owners and funders come from the same record. 32

  8. 08 Maintain

    Service and audit

    Samplers are cleaned and serviced, flow meters verified, sensors recalibrated and software updated in rings. Chain of custody records are audited, and every change is kept with the point record. Spares and procedures travel with the crews. Maintenance history stays with each site for its whole life.

06Data products and integration

What it delivers, to whom, and into which systems.

Data products

  • Normalised wastewater signalsPublic health agencies
  • Sample metadataLaboratories
  • Sampler and flow alertsUtility operators
  • Programme reportsHealth and environment authorities

Integration

  • LaboratoriesSample metadata reach laboratory systems with each sample.
  • Public healthResults join surveillance dashboards with context.
  • UtilitiesSampler alerts reach plant operations.

Exchanged through OPC UA, OGC SensorThings API, HL7 FHIR.

07Questions buyers ask

Before you scope it.

Is it anonymous?

Yes. It measures a whole catchment, not people.

Why flow-proportional?

So results compare across days and rain.

Does the lab change?

No. Laboratories keep their methods and receive better metadata.

Can it watch new pathogens?

Samples can be tested for whatever public health needs.

08Resources

The sources behind this page.

Public standards, regulations and guidance, cited where they apply. Each applies only where its jurisdiction or scope does.

  1. 1Commission Recommendation (EU) 2021/472 on a common approach to establish a systematic surveillance of SARS-CoV-2 and its variants in wastewaters in the EUEuropean Union · 2021
  2. 2Directive (EU) 2024/3019 concerning urban wastewater treatment (recast)European Union · 2024
  3. 3Environmental surveillance for SARS-CoV-2 to complement public health surveillance: interim guidanceWorld Health Organization · 2022

09Related

Use cases and solutions.

Solution

Environmental and permit monitoring

Emissions, water quality, noise and dust monitoring for permit conditions, with traceable calibration and evidence bundles.Solutions for health →
Solution

Sensing as a Service

Observation networks designed, installed, operated and maintained for a monthly fee: weather, hydromet, air, seismic and environmental stations, with data delivered under a licence.Solutions for health →
Solution

Environmental exposure monitoring for health programmes

Heat, air and water exposure measurements around facilities and communities; no diagnosis or treatment.Solutions for health →

10Health: specialized fields

Other fields of this industry.

Specialized field

Heat and health

Street, home and care-home heat sensing linked to heat-health warnings, so health services reach the people most at risk before a heatwave peaks.The full field →
Specialized field

Hospital environments

Ventilation, pressure, temperature, medical gases and pharmacy storage in hospitals, watched continuously so critical rooms stay within their limits and every excursion is on record.The full field →
Specialized field

Mosquito and vector surveillance

Counting traps, weather and standing-water sensing that track mosquitoes and the conditions they breed in, so health authorities target control before outbreaks.The full field →

Bring us the site.

Plan a deployment, configure a station, model it in the Studio or talk to sales. The form names who receives your details.

Plan a deploymentStation BuilderOpen the StudioTalk to salesRequest a quote