Skip to content
Nexus Observatory

/

Education

/

Specialized fields

/

Safe schools

Schools that see hazards coming.

Schools sit on floodplains, in earthquake zones and under summer heat, and they shelter communities after disasters. Sensing at the school, linked to national warnings and the school’s own drills, gives staff minutes to act, shows where buildings need checking and keeps schools open safely.

Plan a deploymentHow it worksStation Builder
Industry
Education
Measurements
4
Sources cited
4
  1. Education · Safe schools

    Places that must stay safe

    Schools sit on floodplains, in earthquake zones and under summer heat, and after disasters they often shelter the whole community. The school safety framework asks for safe buildings, school disaster management and drills, and minutes of warning at the school itself can protect hundreds of children.

  2. What is measured

    Shaking, water and heat

    A strong-motion sensor fixed to the building records shaking. A gauge on the nearest stream or drain measures rising water, and sensors in classrooms and yards measure heat, so each school sees its own hazards rather than a regional average.

    Instruments
    Strong-motion sensor · Flood gauge · Heat sensors
  3. The base node

    Alerts the school can use

    The node detects strong shaking and reports where building checks are needed, raises flood and heat alerts against thresholds agreed with the district, relays national warnings to school displays and records every drill and response. Nothing is lost when a link drops; the node keeps it.

  4. Radio and links

    Independent of the school network

    Alerts and data travel over cellular, independent of the school network, so they work when it fails. A gauge on a stream away from the school reaches it over a low-power link. Each link is chosen for the place, not from a catalogue.

    Links
    Public cellular · LoRaWAN
  5. How it works

    From a rising drain to a safe dismissal

    Heavy rain falls during the school day. The drain gauge beside the school climbs past its threshold; staff receive the alert and follow their plan, holding students on the upper floor and dismissing them by the safe route once the water falls.

  6. From order to operation · Order

    Scope with the district

    The scope reads the district’s schools, hazards, school safety plans and warning arrangements. Nexus Observatory Inc. returns the school kit, alert design, drills support and a price per school and per year. Every assumption in the scope is written down and priced.

    Plan a deployment
  7. From order to operation · Survey

    Survey each school

    Crews visit each school with its safety lead: building type, nearest stream or drain, hot rooms and yards, assembly points and alert displays. Findings are recorded with photographs. Every finding is kept with the site record for the crews who follow.

  8. From order to operation · Permits

    School and authority approval

    The school, district and disaster authority approve the kit and alert rules, and families are told what alerts mean. Every approval is kept with the school record. Approvals are tracked site by site, so nothing waits unseen. No crew goes to site before its approvals are in place.

  9. From order to operation · Build

    Build and test

    Kits are assembled, calibrated, nodes enrolled with their identities and configured with thresholds and warning links. Each kit runs before it ships. Test results travel with the kit to the site. Nothing ships until the whole kit has passed its tests together.

    Open the Station Builder
  10. From order to operation · Install

    Install and mark

    Crews fix the shaking sensor to the building structure, install the flood gauge and heat sensors, mount alert displays and connect backhaul. Every part is photographed and recorded. The site record is updated before the crew leaves. Crews follow the site safety plan throughout the work.

  11. From order to operation · Commission

    Commission with a drill

    Each node proves its identity. Sensors are checked against references, alerts are tested to displays and phones, and the school runs a drill with the system. Response times are recorded. Results are signed and kept with the site record. Acceptance is recorded with the owner before handover.

  12. From order to operation · Operate

    Protect and recover

    Staff receive alerts and act on their plans; after shaking, the district sees which schools need building checks; in heat, outdoor activities change; and every event and drill is recorded. Reports for owners and funders come from the same record.

  13. From order to operation · Maintain

    Drill every term

    Drills are repeated each term, sensors checked and recalibrated on the agreed plan, thresholds reviewed after events, and software updated in rings. Every change is kept with the school record. Spares and procedures travel with the crews. Maintenance history stays with each site for its whole life.

    Book field services
  14. Data products

    For staff, districts and authorities

    School staff receive hazard alerts; district facility teams receive building check lists after shaking; teachers and coaches receive heat guidance; education and disaster authorities receive drill and event records, each tied to school and time. Each product carries its site, time and quality flags.

    See the data products
  15. Evidence

    Safe schools, on record

    The kit supports the comprehensive school safety framework and the safe schools call of the global disaster risk framework, flood levels follow hydrological practice and heat the WMO guide. Every alert, drill and event is kept with the school record.

    Drawn against
    Comprehensive School Safety Framework 2022-2030 · Sendai Framework · WMO-No. 168 · WMO-No. 8
  16. What you get

    Sensing as a Service

    Observation networks designed, installed, operated and maintained for a monthly fee: weather, hydromet, air, seismic and environmental stations, with data delivered under a licence. Delivered as managed service and data licence, for agencies, utilities, municipalities, insurers, agribusiness. Scale: Global, multi-site, per-site pricing.

    Talk to sales
  17. Next step

    Plan safe schools with us

    Tell us the site, the measurements and the rules it answers to. We reply with a survey proposal, a design and a scope for safe schools. An engineer replies with a survey proposal and a scope, and the plan grows from one site to the network you need, at your pace.

    Plan a deploymentOpen the Station BuilderOpen the Studio

01The place and its hazards

Where it runs, and what can go wrong.

Operating contextThe comprehensive school safety framework sets out safe facilities, school disaster management and risk reduction education, and the global disaster risk framework calls for safe schools. Flood levels are gauged to hydrological practice and heat is measured to the WMO guide.

Hazards

  • Floods that reach schools with students inside
  • Earthquakes that damage buildings unseen
  • Heat that makes classrooms unsafe
  • Warnings that never reach the school
  • Schools used as shelters without checks

02What must be measured

What, where, how often, and under which rules.

Each measurement names where it is taken, how often, and the public standard or regulation behind it. Numbers in the sources column open the cited source below.

MeasurementWhereCadenceSources
Ground shakingA strong-motion sensor in the school buildingContinuous, events on shaking1
Flood level near the schoolA gauge on the nearest stream or drainEvery few minutes21
Heat in classrooms and yardsSensors indoors and outdoorsEvery few minutes31
Drills and responsesEach drill and real eventEach event14

03The observation stack

From one base unit to a network.

The same blocks at every scale: instruments and a base node, a site with its radio, a fleet run as one, and a network federated on the open protocol.

  1. 01

    Base unit

    A school kit: shaking, flood and heat sensors on a sensor hub with a small node.

    Build a station →
  2. 02

    Site

    A school: the kit, alert displays and the school’s warning channels.

    Plan a site →
  3. 03

    Fleet

    Every school of a district on one safety view, linked to emergency services.

    Managed offers →
  4. 04

    Network

    Districts share school safety records with education and disaster authorities.

    The open protocol →
  • 01Seismometer / strong-motion accelerometer
  • 02Water level gauge
  • 03Compact weather station
  • 04Sensor and instrument gateway
  • 05Micro node (Nano)
  • 06Cellular modem/router

Radio and links

Public cellular

Alerts and data travel over cellular, independent of the school network.

Radio and links

LoRaWAN

A gauge on a stream away from the school reaches it over a low-power link.

Edge computeThe node detects strong shaking and reports where building checks are needed, raises flood and heat alerts against agreed thresholds, relays national warnings and records drills and responses.

PowerMains with a battery that keeps alerts working through power cuts.

04How it works

From the instrument to the product.

One observation’s path, tier by tier, with the interface on every link and a bill of materials below; then how the one node grows to a site, a fleet and federated networks.

Safe schools: data path

– of 07

01 Instruments Measurement with sensor identity andcalibration 02 Gateway 03 Node – Wrap in an observation envelope with timequality– Measure quality and uncertainty, attachquality flags– Buffer locally (store-and-forward when thelink drops) 04 Backhaul Commit with transactional outbox andpublish, delivered at least once 05 Site Consumer inbox deduplicates and applieseach record once into governed data 06 Data store Governed product through API, map orexport, correction-aware 07 Products CAP 1.2OGC SensorThings APIMQTT 01 Seismometer / strong-motionaccelerometer SDI-12 · RS-485 · Ethernet 02 Water level gauge SDI-12 · RS-485 · Ethernet 03 Compact weather station SDI-12 · RS-485 · Ethernet 04 Sensor and instrument gateway SDI-12 · RS-485 · Analogue I/O ·Ethernet · USB 05 Micro node (Nano) Ethernet · USB · Analogue I/O ·RS-485 · CAN 06 Cellular modem/router Ethernet · USB · RS-232 Site MQTT 5 with Sparkplug B Governed data store Versioned, correction-aware Hazard alerts Building check lists after shaking Heat guidance Drill and event records Ethernet · MQTT 5 SDI-12 · SDI-12 SDI-12 · SDI-12 Ethernet · MQTT 5 Ethernet LTE/NR
From the instrument to the published product: each band is a tier, each connector names its interface, and the numbers match the bill of materials. Hover or focus a block to trace its path; scroll or step to follow one observation.
Bill of materials
ItemEquipmentData portsProtocolsPower in
01Seismometer / strong-motion accelerometerShort-period seismometer or strong-motion accelerometer for local earthquake and structural shaking.SDI-12RS-485EthernetSEED / miniSEED streams, MQTT 5, OGC SensorThings API12 V DC
02Water level gaugeRadar, pressure or float gauge for river, lake, reservoir or tide level.SDI-12RS-485EthernetSDI-12, Modbus, MQTT 5, OGC SensorThings API12 V DC
03Compact weather stationAll-in-one or compact station for temperature, humidity, pressure, wind and rain at a site.SDI-12RS-485EthernetSDI-12, Modbus, MQTT 5, OGC SensorThings API12 V DC
04Sensor and instrument gatewayData logger and gateway that reads instruments on SDI-12, RS-485, analogue and Ethernet ports and publishes observations with calibration and time.SDI-12RS-485Analogue I/OEthernetUSBSDI-12, Modbus, MQTT 5, OGC SensorThings API, OGC API Connected Systems, OMA LwM2M12 V DC, PoE
05Micro node (Nano)Single-board or module-class node for sensor sites, gateways and low-power deployments.EthernetUSBAnalogue I/ORS-485CANMQTT 5, OMA LwM2M, CoAPPoE, 12 V DC, USB PD
06Cellular modem/routerLTE or NR modem or router that uses a public carrier or private network as backhaul.EthernetUSBRS-2323GPP E-UTRA air interface, 3GPP NR air interface, OMA LwM2M12 V DC, PoE

How it scales

01 Instruments Arbitrary qualified sensors and instruments whosemeasurements are ingested with calibration, units,geometry, time, custody and uncertainty. ×n 02 Node The minimum useful deployable unit: server, ruggedappliance, radio node, sensor gateway, satelliteterminal, AI, scientific, vehicle or virtual node. Node Node agent 03 Site The minimum independently operable localgovernance and failure domain: one or more nodesplus local network, identity, policy, evidence,storage, products and operator surfaces.

SITE

Node Node Node ×n 04 Cluster An optional scale or specialisation domain forscheduling, shared storage, accelerators or datalocality.

CLUSTER

×n 05 Fleet Coordinates plans, acknowledgements,convergence evidence, update campaigns andcorrection propagation across nodes and sites.

FLEET

Fleet controller ×n 06 Federation An exchange of products, capabilities, events orwork across approved, independently administeredtrust domains, using explicit trust, policy,data-locality, version and correction contracts.

TRUST DOMAIN

TRUST DOMAIN

TRUST DOMAIN

×n Verifier Applications Data in the field Telemetry Control Data upstream Control Data upstream Control Exchange Evidence Events Exchange
The smallest deployable unit is one node; the same unit is replicated to meet the demand. Nodes form a site, sites may form a cluster, sites and clusters are coordinated as a fleet, and fleets exchange across independently administered trust domains. Each plane is a separate channel with its own open binding.
Data in the field
MQTT 5 with Sparkplug B; connectors for LoRaWAN, OPC UA and instrument buses.
Telemetry
OpenTelemetry OTLP.
Control
TLS 1.3 with mutual authentication; protobuf messages over gRPC or HTTP/2.
Data upstream
At-least-once publication with repeat-safe keys over the control channel or NATS JetStream; QUIC MAY be used on lossy links.
Evidence
DSSE-signed in-toto statements; SLSA provenance; SCITT transparency receipts.
Events
Event envelopes mapped to CloudEvents 1.0; channels described in AsyncAPI 3.
Exchange
OpenAPI 3.1; the OGC API family; SensorThings; STAC; WIS 2.0.

05From order to operation

Every step, from the first call to a running site.

The same crew and the same record carry the work from scope to maintenance.

  1. 01 Order

    Scope with the district

    The scope reads the district’s schools, hazards, school safety plans and warning arrangements. Nexus Observatory Inc. returns the school kit, alert design, drills support and a price per school and per year. Every assumption in the scope is written down and priced. 1

  2. 02 Survey

    Survey each school

    Crews visit each school with its safety lead: building type, nearest stream or drain, hot rooms and yards, assembly points and alert displays. Findings are recorded with photographs. Every finding is kept with the site record for the crews who follow. 1

  3. 03 Permits

    School and authority approval

    The school, district and disaster authority approve the kit and alert rules, and families are told what alerts mean. Every approval is kept with the school record. Approvals are tracked site by site, so nothing waits unseen. No crew goes to site before its approvals are in place.

  4. 04 Build

    Build and test

    Kits are assembled, calibrated, nodes enrolled with their identities and configured with thresholds and warning links. Each kit runs before it ships. Test results travel with the kit to the site. Nothing ships until the whole kit has passed its tests together.

  5. 05 Install

    Install and mark

    Crews fix the shaking sensor to the building structure, install the flood gauge and heat sensors, mount alert displays and connect backhaul. Every part is photographed and recorded. The site record is updated before the crew leaves. Crews follow the site safety plan throughout the work.

  6. 06 Commission

    Commission with a drill

    Each node proves its identity. Sensors are checked against references, alerts are tested to displays and phones, and the school runs a drill with the system. Response times are recorded. Results are signed and kept with the site record. Acceptance is recorded with the owner before handover. 1

  7. 07 Operate

    Protect and recover

    Staff receive alerts and act on their plans; after shaking, the district sees which schools need building checks; in heat, outdoor activities change; and every event and drill is recorded. Reports for owners and funders come from the same record. 14

  8. 08 Maintain

    Drill every term

    Drills are repeated each term, sensors checked and recalibrated on the agreed plan, thresholds reviewed after events, and software updated in rings. Every change is kept with the school record. Spares and procedures travel with the crews. Maintenance history stays with each site for its whole life.

06Data products and integration

What it delivers, to whom, and into which systems.

Data products

  • Hazard alertsSchool staff
  • Building check lists after shakingDistrict facility teams
  • Heat guidanceTeachers and coaches
  • Drill and event recordsEducation and disaster authorities

Integration

  • National warningsNational alerts are relayed to school displays.
  • Emergency servicesEvent records reach emergency services.
  • Facility managementBuilding check lists open inspections.

Exchanged through CAP 1.2, OGC SensorThings API, MQTT.

07Questions buyers ask

Before you scope it.

Does it replace national warnings?

No. It relays them and adds what happens at the school.

Can it tell if a building is damaged?

It shows strong shaking; engineers inspect.

What about heat?

It measures heat indoors and out and advises.

Who acts on alerts?

Staff, following the school’s own plan.

08Resources

The sources behind this page.

Public standards, regulations and guidance, cited where they apply. Each applies only where its jurisdiction or scope does.

  1. 1Comprehensive School Safety Framework 2022-2030Global Alliance for Disaster Risk Reduction and Resilience in the Education Sector · 2022
  2. 2WMO-No. 168: Guide to Hydrological PracticesWorld Meteorological Organization
  3. 3WMO-No. 8: Guide to Instruments and Methods of ObservationWorld Meteorological Organization
  4. 4Sendai Framework for Disaster Risk Reduction 2015-2030United Nations Office for Disaster Risk Reduction · 2015

09Related

Use cases and solutions.

Use case

School connectivity observatory

A connected school as an observatory node: backhaul, Wi-Fi, a connectivity probe and an optional weather and air-quality station.The full use case →
Use case

Citizen seismology node

A compact seismograph on a network connection, registered in an open seismic data network.The full use case →
Solution

Sensing as a Service

Observation networks designed, installed, operated and maintained for a monthly fee: weather, hydromet, air, seismic and environmental stations, with data delivered under a licence.Solutions for education →
Solution

Structural and ground-movement monitoring

GNSS, InSAR, tilt, strain and fibre sensing on bridges, dams, slopes, tailings and pipelines, with alert thresholds set by the owner.Solutions for education →

10Education: specialized fields

Other fields of this industry.

Specialized field

School observatories

Weather, air quality and seismic stations at schools that students run, with real data for lessons, shared with networks that can use them.The full field →
Specialized field

Classroom air and ventilation

Carbon dioxide, temperature, humidity and particle sensing in every classroom, so schools ventilate when needed, keep rooms comfortable and show parents the air is good.The full field →
Specialized field

Technician training and qualification

Training labs with real stations, calibration benches and network equipment, where technicians learn to install, calibrate and repair observing systems and earn recognised qualifications.The full field →

Bring us the site.

Plan a deployment, configure a station, model it in the Studio or talk to sales. The form names who receives your details.