title: "From instrument to product | Observatory Protocol"
description: "The Observatory Protocol at work, drawn from its own data: how a node joins, how one observation travels, how conformance is reached, how grids federate…"
url: https://nexusobservatory.com/explainers/data-paths/
publisher: GCRI Canada
updated: 2026-11-20
---

[Observatory Protocol](https://nexusobservatory.com/)[Learn](https://nexusobservatory.com/learn/)From instrument to product, one observation

# One observation, from the instrument to the product.

Each band is a tier, each connector names its interface, and the value keeps its time, quality and provenance all the way to the published product.

**Version**: 0.1.0-draft
**Status**: Draft specification
**Specification**: CC BY 4.0
**Code**: Apache-2.0
**Steward**: GCRI Canada
**Source**: obsp-0.1-foundation

Follow it

[Read the specification](https://nexusobservatory.com/spec/flows/)

## GBON gap-filler station

A WMO-grade surface station, optional upper-air ground station and a WIS 2.0 node, built to report reliably where the global basic observing network has gaps.

GBON gap-filler station: data path

– of 06

01 Instruments Measurement with sensor identity and calibration 02 Node – Wrap in an observation envelope with time quality – Measure quality and uncertainty, attach quality flags – Buffer locally (store-and-forward when the link drops) 03 Backhaul Commit with transactional outbox and publish, delivered at least once 04 Site Consumer inbox deduplicates and applies each record once into governed data 05 Data store Governed product through API, map or export, correction-aware 06 Products WMO-No. 8 (CIMO Guide) WMO-No. 1160 (Manual on WIGOS, GBON) WMO WIS 2.0 WMO-No. 306 (BUFR) 07 Power and structure Supplies 12 V DC, 24 V DC, 48 V DC to the field equipment 01 Automatic weather station (WMO class) SDI-12 · RS-485 · Ethernet 02 Radiosonde ground station SDI-12 · RS-485 · Ethernet 03 Edge node (Wedge) Ethernet · Fibre · USB · RS-485 · BMC 04 VSAT dish terminal Ethernet · RF 05 Cellular modem/router Ethernet · USB · RS-232 Site MQTT 5 with Sparkplug B Governed data store Versioned, correction-aware Hourly and sub-hourly BUFR observations to WIS 2.0 National open data and verification feeds Reporting-uptime evidence 06 Solar array RS-485 07 Telescopic mast RS-485 Ethernet Ethernet Ethernet Satellite IP LTE/NR

From the instrument to the published product: each band is a tier, each connector names its interface, and the numbers match the bill of materials. Hover or focus a block to trace its path; scroll or step to follow one observation.

| Item | Equipment | Data ports | Protocols | Power in |
| --- | --- | --- | --- | --- |
| 01 | **Automatic weather station (WMO class)** Automatic weather station built and sited to WMO-No. 8 instrument and siting classes, reporting WIGOS metadata. | SDI-12 RS-485 Ethernet | SDI-12, Modbus, MQTT 5, OGC SensorThings API | 12 V DC |
| 02 | **Radiosonde ground station** Ground receiver and launch station for balloon-borne radiosondes reporting upper-air profiles. | SDI-12 RS-485 Ethernet | SDI-12, Modbus, MQTT 5, OGC SensorThings API | AC mains |
| 03 | **Edge node (Wedge)** Rugged edge node that boots from signed media, attests itself and establishes a site cell from little or no infrastructure. | Ethernet Fibre USB RS-485 BMC | MQTT 5, DMTF Redfish, IEEE 1588 PTP, NTP with NTS, OPC UA | 12 V DC, 24 V DC, 48 V DC, AC mains |
| 04 | **VSAT dish terminal** Parabolic earth-station terminal on a pan-tilt or fixed mount for GEO or MEO links. | Ethernet RF | — | AC mains, 48 V DC |
| 05 | **Cellular modem/router** LTE or NR modem or router that uses a public carrier or private network as backhaul. | Ethernet USB RS-232 | 3GPP E-UTRA air interface, 3GPP NR air interface, OMA LwM2M | 12 V DC, PoE |
| 06 | **Solar array** PV modules with charge controller sized to the site's load and climate. | RS-485 | Modbus | — |
| 07 | **Telescopic mast** Pneumatic or winch telescopic mast on a trailer, vehicle or base. | — | — | — |

Figure 1GBON gap-filler station

## Street flood observatory

Ultrasonic depth sensors on poles report street-level water depth as open data and alerts.

Street flood observatory: data path

– of 07

01 Instruments Measurement with sensor identity and calibration 02 Field radio 03 Gateway 04 Backhaul 05 Site Consumer inbox deduplicates and applies each record once into governed data 06 Data store Governed product through API, map or export, correction-aware 07 Products OGC SensorThings API 1.1 Municipal open-data terms 08 Power and structure Supplies 12 V DC to the field equipment 01 Water level gauge SDI-12 · RS-485 · Ethernet 02 LPWAN endpoint Analogue I/O · SDI-12 · RS-485 03 LoRaWAN gateway Ethernet · RF · GNSS antenna IP backhaul Not in the reference kit Site MQTT 5 with Sparkplug B Governed data store Versioned, correction-aware Street-level water depth time series Open data feed and alerts to emergency management and 311 04 Solar array RS-485 05 Pole SDI-12 LoRaWAN Ethernet IP

From the instrument to the published product: each band is a tier, each connector names its interface, and the numbers match the bill of materials. Hover or focus a block to trace its path; scroll or step to follow one observation.

| Item | Equipment | Data ports | Protocols | Power in |
| --- | --- | --- | --- | --- |
| 01 | **Water level gauge** Radar, pressure or float gauge for river, lake, reservoir or tide level. | SDI-12 RS-485 Ethernet | SDI-12, Modbus, MQTT 5, OGC SensorThings API | 12 V DC |
| 02 | **LPWAN endpoint** Battery-powered endpoint on LoRaWAN, NB-IoT or LTE-M that carries one or more sensors. | Analogue I/O SDI-12 RS-485 | LoRaWAN, OMA LwM2M, CoAP | Internal battery, Energy harvesting |
| 03 | **LoRaWAN gateway** Multi-channel LoRaWAN gateway that forwards uplinks to a network server and schedules downlinks within duty limits. | Ethernet RF GNSS antenna | LoRaWAN, MQTT 5 | PoE, 12 V DC |
| 04 | **Solar array** PV modules with charge controller sized to the site's load and climate. | RS-485 | Modbus | — |
| 05 | **Pole** Utility, street or dedicated pole with clamp positions. | — | — | — |

Figure 2Street flood observatory

## Hybrid air-quality observatory

A few reference analysers and many low-cost nodes, with co-location calibration and an open-data feed.

Hybrid air-quality observatory: data path

– of 07

01 Instruments Measurement with sensor identity and calibration 02 Gateway 03 Node – Wrap in an observation envelope with time quality – Measure quality and uncertainty, attach quality flags – Buffer locally (store-and-forward when the link drops) 04 Backhaul Commit with transactional outbox and publish, delivered at least once 05 Site Consumer inbox deduplicates and applies each record once into governed data 06 Data store Governed product through API, map or export, correction-aware 07 Products EU Directive 2024/2881 (ambient air quality) CEN/TS 17660 (sensor systems) US EPA FEM/FRM reference methods 08 Power and structure Supplies 12 V DC to the field equipment 01 Air quality monitor SDI-12 · RS-485 · Ethernet Low-cost air-quality nodes with LoRaWAN radios Not in the reference kit 02 LoRaWAN gateway Ethernet · RF · GNSS antenna 03 Micro node (Nano) Ethernet · USB · Analogue I/O · RS-485 · CAN 04 Cellular modem/router Ethernet · USB · RS-232 Site MQTT 5 with Sparkplug B Governed data store Versioned, correction-aware Air-quality index and hyperlocal maps, labelled supplementary Calibrated time series with quality flags Publication route to an open air-quality aggregator 05 Solar array RS-485 LoRaWAN RS-485 Ethernet Ethernet LTE/NR

From the instrument to the published product: each band is a tier, each connector names its interface, and the numbers match the bill of materials. Hover or focus a block to trace its path; scroll or step to follow one observation.

| Item | Equipment | Data ports | Protocols | Power in |
| --- | --- | --- | --- | --- |
| 01 | **Air quality monitor** Particulate and gas monitor (PM, NO2, O3, CO, SO2) for outdoor or indoor air. | SDI-12 RS-485 Ethernet | SDI-12, Modbus, MQTT 5, OGC SensorThings API | 12 V DC |
| 02 | **LoRaWAN gateway** Multi-channel LoRaWAN gateway that forwards uplinks to a network server and schedules downlinks within duty limits. | Ethernet RF GNSS antenna | LoRaWAN, MQTT 5 | PoE, 12 V DC |
| 03 | **Micro node (Nano)** Single-board or module-class node for sensor sites, gateways and low-power deployments. | Ethernet USB Analogue I/O RS-485 CAN | MQTT 5, OMA LwM2M, CoAP | PoE, 12 V DC, USB PD |
| 04 | **Cellular modem/router** LTE or NR modem or router that uses a public carrier or private network as backhaul. | Ethernet USB RS-232 | 3GPP E-UTRA air interface, 3GPP NR air interface, OMA LwM2M | 12 V DC, PoE |
| 05 | **Solar array** PV modules with charge controller sized to the site's load and climate. | RS-485 | Modbus | — |

Figure 3Hybrid air-quality observatory

## More explainers.

- [Explainer **How a node joins the grid**](https://nexusobservatory.com/explainers/how-a-node-joins/)
- [Explainer **Conformance, level by level**](https://nexusobservatory.com/explainers/conformance-levels/)
- [Explainer **From one node to federated grids**](https://nexusobservatory.com/explainers/federation/)
- [Explainer **A lineage of shared observation**](https://nexusobservatory.com/explainers/lineage/)
- [Explainer **Open schemas, one contract**](https://nexusobservatory.com/explainers/open-schemas/)

On this page

1. GBON gap-filler station
2. Street flood observatory
3. Hybrid air-quality observatory
4. More explainers.

- [View the source](https://nexusobservatory.com/development/text/)
- [Report a defect](https://nexusobservatory.com/development/take-part/)
- [Propose a change](https://nexusobservatory.com/development/proposals/)
- [Changes](https://nexusobservatory.com/governance/changes/)